TA660 User's Manual

Catalyst Enterprises, Inc

44

Scan Configuration Registers

To perform a configuration scan select Scan Configuration
Registers
from the Exerciser dropdown list on the menu bar.

The system will search for PCI devices on the bus and display the
configuration as shown in Figure 41. All devices on the bus are
reported. To see information on additional devices click Next>.

Figure 41 Configuration Header Display Dialog Box

You may edit all of the parameters displayed in white, if your
hardware allows it. Edit the field and then click on the "Write PCI
Configuration to this Device" button.

To save configuration read all devices, find your device and save it to
a file.

PCI 2.1 or PCI 2.2 Specification

Scan check may be performed to either the

PCI 2.1 or PCI 2.2 specification. The selection of which
specification is made on the Software Global Settings dialog
box. To set these options click Configuration on the main
menu bar and then choose Software Settings.