Analyzer Settings

94

 

 

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual

2.15.3

Show XXXX value

Check this option to display XXXX values.

Pack training sequence

Checking this box allows hiding the details of the Training Sequence, which can take up 
large portions of the trace unless packed.

ALIGN Transmission Period (differs for SAS and SATA)

Choose the ALIGN Transmission Period for SSP and STP by clicking the corresponding 
option button, then open the Protocol Error Mask dialog.

2.15.4

Protocol Error Mask

Click the Protocol Error Mask button to open the Protocol Error Mask dialog.

Figure 2.66: Protocol Errors Dialog

Check the Protocol Errors that you want the Analyzer to ignore.

When “RD Error” and “Code violation Error” are set as trigger events: 
“RD Error” or “Code violation Error” can occur right after the OOB sequence.
“RD Error” or “Code violation Error” can occur right after the recovery from the PM state.

These errors are mainly caused by the long synchronization time of the analyzer. If these 
errors, caused by the Analyzer, become triggers, you cannot detect some other errors 
that you really need to detect. To NOT detect the above two errors, enable the software 
setting Disable ‘Disparity Error’ and ‘Symbol Violation’ during Speed negotiation. After 
this, the code violation is not triggered during the speed negotiation phase, but is 
triggered if the violation happens after the speed negotiation phase. 