Qphy-usb software option, Hub high-speed upstream repeater – Teledyne LeCroy QPHY-USB User Manual

Page 37

Advertising
background image

QPHY-USB Software Option

QPHY-USB Operator’s Manual Rev F

37

HUB HIGH-SPEED UPSTREAM REPEATER

Figure 36. Hub and Device Fixture Connections for Upstream Repeater Test

1. Select Hub in the Mode control and HS Upstream Repeater in the Test control of the USB Test Wizard.

Note: Longer cables and/or adapters may be used to ease connection of Mini-B and Micro-B connectors.

2. Follow the instructions in the USB Test Wizard to acquire the waveforms as shown:

Figure 37. Initial signal acquisition for hub upstream repeater test

The second packet is the device signal. It passes upstream to the hub (C4) and the hub repeats it to the host
(C1).