QPHY-USB Operator’s Manual Rev F

Test Results

Bus-powered

Hub

Self-powered

Hub/System

Laptop

Battery powered

Self powered

Load type

100 mA

500 mA

__100__500 mA

500 mA

V

NL

V

LOADED

V

UPSTREAM

V

DOWNSTREAM

V

DROP

V

DROOP

Less than

330 mV

Reporting Results

No Load Voltage: passing values are from 4.75 to 5.25 V

Loaded Voltage: passing values are from 4.75 to 5.25 V

Upstream Voltage: passing values are from 4.40 to 5.25 V

Downstream Voltage: passing values are from 4.75 to 5.25 V

Voltage Drop

Droop Voltage

Note: Please do not connect a Hub or a Host to the droop fixture longer than 5 minutes. Resistance may become unstable under high