SDAIII-CompleteLinQ Software

SDA Framework Dialog

This SDAIII-CompleteLinQ Framework dialog is the main configuration screen for all serial data analysis. It
represents the overall flow for viewing and analyzing serial data, beginning with

lane configuration

at the

left, through Eye, Jitter, Vertical Noise and Crosstalk measurement at the right.

Each block in the flow diagram is a button that, when touched, displays its corresponding configuration
dialog. Some options will be enabled or disabled depending on your SDAIII-CompleteLinQ installation.

The Framework dialog is invoked by choosing Analysis > Serial Data from the menu bar.

Integrated Operation

If you're using Eye Doctor II or VirtualProbe in conjunction with SDAIII-CompleteLinQ, use the Frame-
work dialog to configure emphasis, de-embedding/emulation and equalization for the active lane.

Dialog Elements

Enable SDA checkbox - By default checked to enable all views and analyses selected within the SDAIII-
CompleteLinQ environment. Unchecking this box will globally disable analysis and turn off all views.

Quick View button - Touch to open the

Quick View

to configure lane settings.

CAUTION: Using Quick View will clear the current configuration of the selected lane and instead apply the
configuration made within the Quick view window.

Lane 1-4 selector buttons - Touch to activate the lane for configuration. The text displayed beneath each
button in the SDA dialog gives information about the setup for the selected lane.

Ref Lane button - Touch to display the reference lane. This lane stores the data and views from another
lane for comparison purposes (see Store Lane to Ref button below). The name of the stored lane appears
to the right of the button when in use.

NOTE: The Reference Lane is unavailable for use when you enable VirtualProbe capabilities on the De-
embed/Emulate dialog.

Lane Enable/Disable checkboxes - Check to enable the corresponding lane for display/analysis. When
multiple lanes are checked, the oscilloscope will enter

LaneScape Comparison Mode

and display each

lane in its own frame, and the Comparison Mode selection box will be active at the top right of the
screen.

Store Lane to Ref button - Touch to store the setup and data of the active lane to the reference lane.

NOTE: When VirtualProbe is enabled within the De-embed/Emulate dialog, the reference lane is unavail-

able, and the Store Lane to Ref button is disabled.

Copy Lane Setup button - Touch to open a window for copying the setup and data from one lane to
another.