The standard EN 1570 does not establish the
additional requirements for:

~ Operation in severe conditions (e.g. extreme climates, freezer
applications, strong magnetic fields.).
~ Operation subject to special rules (e.g. potentially explosive
atmospheres, mines).
~ Handling of loads, the nature of which could lead to dangerous
situations (e.g. molten metal, acids, radiating materials, especially
brittle loads).
~ Hazards occurring during construction, transportation and
disposal.
~ Equipment installed on the load platform or replacing it.
~ Integration into systems or other machines, control from more
than two control stations etc.
~ Cable-less controls.
~ Lifting tables where the hydraulic pressure is derived directly
from gas pressure.

TECHNICAL DETAILS:

Hydraulic Fluid:

ISO VG22

Hydraulic Hoses:

TRACTOR 1T EN 853 1SN
Insert:

MF2000

Multifit

Type

Tube:

Oil

resistant

synthetic

rubber

Reinforcement:

One high tensile steel braid

Cover: Environmental resistant synthetic rubber
Max. working pressure: 225 bar (3260 psi)