o 1. Connect the positive lead of the 0-10 VDC

input to terminal 3 of terminal block TB1.
Securely tighten the screw.

o 2. Connect the negative lead of the 0-10 VDC

input to terminal 2 of terminal block TB1. Snug
terminal only.

o 3. Connect the shield wire to terminal 2 of

terminal block TB1. Securely tighten the screw.

o 4. Locate the five-position jumper mounted on

the board on the inside cover of the TCS-200-1.
Remove the two position black selector from
positions 4 & 5 of jumper JP1 and discard.

4-20 mA
Refer to Figure 5c for the 4-20 mA Analog input
connections.

o 1. Connect the positive lead of the 4-20 mA input

to terminal 4 of terminal block TB1. Securely
tighten the screw.

o 2. Connect the negative lead of the 4-20 mA

input to terminal 2 of terminal block TB1. Snug
terminal only.

o 3. Connect the shield wire to terminal 2 of

terminal block TB1. Securely tighten the screw.

o 4. Locate the five-position jumper mounted on

the board on the inside front cover of the
TCS-200-1. Remove the two position black
selector from positions 4 & 5 of jumper JP1 and
discard.

Isolation Power Supply

Refer to Figure 5d for analog input isolation power
supply connections.

Note: To isolate the analog input from the TCS-200-1
control ground, a separate 15-35 VDC voltage supply
is needed.

o 1. Connect the positive side of the 15-35 VDC

external voltage supply to terminal 1 of terminal
block TB1. Securely tighten the screw.

o 2. Connect the negative side of the 15-35 VDC

external voltage supply to terminal 2 of terminal
block TB1. Securely tighten the screw.

System Start-Up and Adjustment

Manual Tension Adjust (Front Panel)

o 1. Apply power to the control system.

o 2. Check that the green LED marked “power” is

illuminated.

o 3. Using an AC voltmeter, measure the AC input

voltage at terminals 4 and 8 of terminal block
TB2. This voltage should be 115 or 230 VAC,
depending on the voltage chosen.

o 4. Remove power from the control system and

wait approximately 30 seconds before
proceeding to the next step.

Electro Disc Tension Brake

Note: If you are not using electro disc tension
brakes, proceed to step 5 under all other 2 wire
tension brakes section.

o 5. Remove the sense magnet lead from terminal

1 of terminal block TB2 and insert a DC current
meter between the lead of the sense magnet and
terminal 1 of terminal block TB2. Note: Use a DC
current meter that reads 0 to 500 mA with the
Positive (+) lead connected to terminal 1 and
negative (-) lead connected to the wire.

o 6. Reapply power to the control system.

o 7. Place the mode selector switch in the brake

“off” position. The meter should read zero
current and the brake should free wheel.

o 8. Place the mode selector switch in the brake

“on” or “stop” position. The meter should read
345 to 375 mA and the brake should be locked.