Warner Electric TCS-200-1H User Manual

Page 14

Advertising
background image

14

Warner Electric • 800-825-9050

P-2003-2 • 819-0420

o 15. Adjust the front panel tension adjust

potentiometer to the maximum output level
required for the application. Now set the remote
tension adjust potentiometer between maximum
and zero.

Note: If start-up and adjustment procedures do not
produce the desired results, consult the
troubleshooting section of this manual.

o 16. If a remote mode selector switch is used,

repeat steps 5 through 13 using the remote
mode selector switch.

o 17. Close the control front cover and latch it by

tightening the screw that is provided.

Roll Follower Tension Adjust

o 1. Apply power to the control system.

o 2. Check that the green LED marked "power" is

illuminated.

o 3. Using an AC voltmeter, measure the AC input

voltage at terminals 4 and 8 of terminal block
TB2. This voltage should be approximately 115
or 230 VAC, depending on the voltage chosen.

o 4. Remove power from the control system and

wait approximately 30 seconds before
proceeding to the next step.

Electro Disc Tension Brake

Note: If you are not using electro disc tension
brakes, proceed to step 5 under all other 2 wire
tension brake section.

o 5. Remove the sense magnet lead from terminal

1 of terminal block TB2 and insert a DC current
meter in series with the lead of the sense magnet
and terminal 1 of terminal block TB2.

Note: Use a DC current meter that reads 0 to 500
mA with the positive (+) lead connected to terminal 1
and the negative (-) lead connected to the wire.

o 6. Reapply power to the control system.

o 7. Set the mode selector switch to the brake

“off” position. The meter should read zero current
and the brake should free wheel.

o 8. Place the mode selector switch in the brake

“stop" position. The meter should read 345 to
375 mA and the brake should be locked.

o 9. Place the mode selector switch in the brake

"run" position and set the tension adjust
potentiometer to its maximum (fully clockwise)
setting.

Note: Refer to Table 1 for various inputs and outputs
when using the roll follower system

o 10. Connect a second DC voltmeter between

terminals 9 and 11 of terminal block TB1.

Note: Use a DC voltmeter capable of measuring zero
to 10 volts DC.

o 11. With the roll follower potentiometer

disconnected from the roll follower arm, position
the follower arm to its true zero position, which
should be the centerline of the unwind spindle.

o 12. Adjust the roll follower potentiometer to a

zero voltage reading on the voltmeter which is
connected per step 10, page 14.

o 13. Connect the roll follower potentiometer to the

roll follower arm. After coupling the follower arm
to the potentiometer, recheck the voltage
between terminals 9 and 11 of terminal block
TB1 to insure the voltage is still zero VDC.

o 14. Place a full roll of material on the unwind

stand.

o 15. Set the roll follower arm on the unwind roll.

o 16. Check the voltage between terminals 9 and

11 of terminal block TB1 and refer to Table 1. If
the voltage reading is less than 0.8 VDC, refer to
Table 1 for the nominal output current available.

Advertising