Electrical installation, Electrical connections – Warner Electric AC10 Measuring System User Manual

Page 10

Advertising
background image

10

Warner Electric • 800-825-9050

P-2012-2

Electrical Installation

(Read the entire electrical installation proce-
dure before proceeding.)

The PSAC10 Power Supply/Amplifier board
should be securely mounted in a cabinet or
enclosure using the mounting holes and standoffs
INPUT provided. Refer to the dimension drawing
on Page 19 for mounting hole locations.

Two 30 foot cables are provided for connecting
the AC10 Tensioncells with the PSAC10 board. A
screw-on connector is provided at one end of
each cable for connecting to the AC10
Tensioncells.

Note: If the board must be located more than
30 feet away from the Tensioncells, the cable
can be extended up to a total of 100 feet using
Belden #8723 (or equivalent) in a grounded steel
conduit.

Oscillator

Demodulator

Shield to Pin H

Shield to Pin H

White to Pin G

Brown to Pin A

Pink to Pin E

Yellow to Pin C

Input

Output

P1

S1

S2

A G H

E

C

A H G

C

D

E

F

B

Electrical Connections

Although either Tensioncell in the system can be
designated as Tensioncell #1 or #2, the following
electrical connections assume the AC10
Tensioncell marked W1 is Tensioncell #1 and the
Tensioncell marked W2 is Tensioncell #2.

Notes:
1. The wire color connections listed for J1 and

J2 will differ if Belden #8723 (or equivalent)
cable is required. lnsure the correct wiring
connections are made with respect to the
connection made with the Warner Electric
supplied cable.

2. The Warner Electric supplied cable/connec-

tor assembly is an eight conductor cable.
However, only the yellow, pink, brown, and
white and shield wires used.

J1 to W1 Tensioncell Terminal Connection
with Warner Electric supplied cable

Terminal

Label

Description

Wire Color

J1-1

Sig

AC signal from LVDT

Yellow

J1-2

Sig

AC signal from LVDT

Pink

J1-3

Exc

Excitation to LVDT

Brown

J1-4

Exc

Excitation to LVDT

White

J1-5

Gnd

Shield

Shield

Sig
Sig
Exc
Exc
Gnd

Yellow
Pink
Brown
White

Shield

Yellow
Pink
Brown
White

Shield

Sig
Sig
Exc
Exc
Gnd

J2

J1

1

1

2

2

3

3

4

4

5

5

Tension signal from transducer 0-700mVAC, 5KHz

15 VAC, 5KHz excitation to the transducer

Tension signal from transducer 0-700mVAC, 5KHz

15 VAC, 5KHz excitation to the transducer

Warner Electric Supplied Cable to Transducers

Note: Pins B, D & F are not used

Advertising