13

Warner Electric • 800-825-9050

P-2012-2

AC10 Setup Procedure

Important: The input to any external device
wired to J6-3 Out1 or J6-1 Out 2 must be 10
VDC or less.

The following procedure assumes a digital volt-
meter will be used when measuring and setting
the desired output voltages. If the outputs are
connected to a digital or analog indicating
device, which will be used during normal opera-
tion, these devices may be used during the setup
procedure.

Note: The voltage setting for Output #1 at
100% load must be more positive than the
voltage setting at 0% load. The same
applies to the voltage settings for Output #2.

With power applied to the PSAC10 board, allow
the system to "warmup" for 20 minutes or
longer before proceeding with the setup proce-
dure.

1. Press and release the SETUP and UP-

ARROW keys simultaneously. An asterisk (*)
will display next to the

right tension value.

0%

0%

*0%

2. Press and release SETUP & ENTER simulta-

neously to start the SETUP procedure.

Note: The Run Mode LED should stop flashing.

Compression Mode

3. Select either the COMPRESSION MODE or

TENSION MODE using the UP or DOWN
arrow key to toggle between the two choices.

a. Select the COMPRESSION MODE if the

direction of the tension force is toward the
base block.

b. Select TENSION MODE the direction on

the tension force is away from the base
block.

C

om

pr

es

si

on

Te

ns

io

n

4. Press ENTER when the desired mode is dis-

played.

Steps 5 through 8 are performed with only
the tare load applied on the Tensioncells.

Note: To exit the SETUP mode at anytime dur-
ing the following procedure, press and release
the EXIT key. The system will return to the set-
tings entered during the last completed setup.

5. Apply Load 0%

Insure that the Tensioncells are properly
installed and the material is removed from
the measuring roll.

6. Press ENTER.

Advertising