Warner Electric AC10 Measuring System User Manual

Page 11

Advertising
background image

11

Warner Electric • 800-825-9050

P-2012-2

J2 to W2 Tensioncell Connection with Warner
Electric supplied cable

Terminal

Label

Description

Wire Color

J2-1

Sig

AC signal from LVDT

Yellow

J2-2

Sig

AC signal from LVDT

Pink

J2-3

Exc

Excitation to LVDT

Brown

J2-4

Exc

Excitation to LVDT

White

J2-5

Gnd

Shield

Shield

J3 Input Power (115/230 VAC, 1-PH, 50/60 Hz)

Terminal Label

Description Wire

Color

J3-1

Gnd

Ground

Green

J3-2

L1

L1 (230V) or Hot (115V)

Black

J3-3

L2

L2 (230V) or Neutral (115V) White

The input voltage selector switch must corre-
spond to the voltage of the input power
source.

J4 AC Power Switch and/or Power Indicator
Terminal

J4 provides the terminal connection for an exter-
nal AC Power Switch and/or power indicator. The
indicator should not draw more than 40 milliamps
of current. J4 may also be used to supply AC
power to a digital voltmeter by connecting the
meter between J4-2L1 and J4-2L2.

Note: If an ON-OFF switch is not used,
jumpers must be installed from J4-2L1 to
J4-1L1 and from J4-2L2 to J4-1L2 for
proper operation.

Gnd
L1
L2

J3

230V

1

2

3

Make sure voltage select
switch is in proper position

Input Power single phase
115 or 230 VAC

X

X

2-Only

1-Only

Gnd

J5

Cell #2

Cell #1

Total

1

2

3

Terminal

Label

Description

J4-1

2L1

(Switched) Line 1

J4-2

1L1

(Hot) Line 1

J4-3

2L2

(Switched) Line 2

J4-4

1L2

(Hot) Line 2

J5 Cell#1/Total/Cell#2 Switch Terminal (For
Output #2 only)

J5 provides the connections for an external
three-position switch with two normally open
contacts. When used in conjunction with a
remote meter, the switch allows the user to
monitor total tension or the tension applied to
either Tensioncell. The meter should be connect-
ed to Output #2 at J6, terminals Out2 and Gnd.

With the switch in the normally closed position,
Output #2 will indicate the total tension. In the
Cell#1 position, Output #2 switches to indicate
the tension measured by the W1 Tensioncell.
Changing to the Cell#2 position switches Output
#2 to indicate the tension applied to the W2
Tensioncell.

Terminal

Label

Description

J5-1

2-Only

(Switched) tension W1

J5-2

1-Only

(Switched) tension W2

J5-3

Gnd

Ground

2L1

1L1

2L2

1L2

J4

1

2

3

4