© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

F232182

18

6. Press the Start key.

7. Use the Up or Down key to select the desired

supply option. Refer to Table 6.

Table 6

8. Press the Start key.

9. If the temperature-controlled fill or the auxiliary

heat setup option is enabled, use the Up or Down
key to select the desired segment temperature. To
disable auxiliary heat and temperature-controlled
fill for this segment, set this value to zero. Press
the Start key.

NOTE: If the temperature-controlled fill setup
option is enabled and an auxiliary fill has been
selected for the segment, the segment temperature
should be set to zero. Otherwise, the auxiliary fill
valve will enable for only three seconds at the
beginning of the fill before the computer begins
using the hot and cold fill valves to reach the
programmed temperature.

10. Use the Up or Down key to select the desired

drain option. If “drAI” is selected, the machine
will drain after the segment time has elapsed. If
“nodr” is selected, the machine will not drain and
the spin step will be skipped entirely. Press the
Start key.

NOTE: The drain step in the final segment (Fill 9)
cannot be skipped.

11. For final “FIL9” spin only, use the Up or Down

key to select the desired spin speed. Refer to
Table 7.

Table 7

12. Press the Start key.

13. Use the Up or Down key to select the desired spin

time. Set this value to zero to skip the spin step.
Press the Start key. The display will now show
the identifier for the next program segment (or
return to the temperature display if the edited
segment is the Fill 9 segment).

NOTE: Every intermediate spin is followed by a
25 second coast-down period, which occurs during
the fill step for the following segment.

14. Press the Stop key at any time to complete the

cycle programming procedure.

Supply Options

Display

Supply

SUP0

No Supply

SUP1

Supply 1

SUP2

Supply 2

SUP3

Supply 3

SUP4

Supply 4

SUP5

Supply 5*

SUP6

Supply 1 and 5*

SUP7

Supply 3 and 4

*This is available only if the “SUP5”/“AFIL” setup

option is set to “SUP5.”

Spin Options

Display

Spin Speed

SPn1

Low Spin

SPn2

Medium Spin

SPn3

High Spin

Advertising