Programming

23

F232182

Segments 3 – 10 (Fills 1 – 8)

Display

Instructions

Use Up or Down key to change. Press Start key to enter or advance.

FIL1, FIL2, FIL3, FIL4, FIL5, FIL6, FIL7, or FIL8

00 or 02 to 15

Select segment time: 02 to 15 minutes (00 to skip segment).

tFIL

Indicates temperature fill is enabled.*

HFIL, CFIL, bFIL,
or AFIL

Select “HFIL” (hot fill), “CFIL” (cold fill), “bFIL” (warm fill), or “AFIL” (auxiliary fill).**

Lo,

n

Ed, or HI

Select fill level: “Lo” (low), “

n

Ed” (medium), or “HI” (high) water level.

SUP0 – SUP7

Select supply 0 – 7 (0 for no supply).***

00°F, 75° – 200°F
00°C, 25° – 93°C

Select temperature: 75° to 200°F or 25° to 93°C (00 for no heat).†

drAI or nodr

Select drain option: “drAI” (drain), “nodr” (no drain).‡

SPIn (flashed for one second)

tI

n

E (flashed for one second)

00 or 30 to 240

Select time for spin: 30 to 240 seconds (00 for no spin).

* This is displayed only if temperature-controlled fills are enabled in the setup options and if the heat temperature is set to
a value other than “00.”
** “AFIL” can be selected only if the “SUP5”/“AFIL” setup option is set to “AFIL.”
*** “SUP5” and “SUP6” can be selected only if the “SUP5”/“AFIL” setup option is set to “SUP5.”
† This value is not available when temperature-controlled fill and auxiliary heat setup options are disabled.
‡ If “nodr” is selected, the computer skips the spin step and goes on to the next segment.