635/636 CONTROL BOARD ADJUSTMENTS

PROGRAM SWITCHES

Factory Description

Setting

#1

ON

TIMER TO CLOSE - Automatically closes gate

ON - Close timer enabled OFF - Close timer disabled


#2

OFF

CURRENT SENSITIVITY OPTION - Delays current sensing from start

ON - 4 second delay OFF - 2 second delay


#3

ON

TIMER TO CLOSE OPTION

ON - timer to close works only when open limit switch is activated

OFF - timer to close works from any open gate position

#4

OFF

DUAL CONTROL SLAVE OPTION

ON - disables slave side of dual board

OFF - enables slave side of dual board

#5

OFF

DUAL CONTROL MASTER OPTION

ON - disables master side of dual board

OFF - Enables master side of dual board

#6

OFF

MAXIMUM RUN TIMER OPTION

ON - stops and reverses gate if run timer times out before closing

OFF - stops gate if run timer times out before closing

#7

ON

MAXIMUM RUN TIMER VALUE

ON - 40 seconds

OFF -20 seconds

#8

ON

TIMER TO CLOSE VALUE

ON - 20 to 70 seconds (adjustable)

OFF - 10 to 35 seconds (adjustable)

#9

OFF

OPEN, STOP, CLOSE CONTROL ENABLE

ON - allows for open, stop, close unit (optional) to operate gate

OFF - normal operation

(If 9 is on, terminals 4 & 5 must be normally closed for proper operation.)

TIMER TO CLOSE ADJUSTMENT


Rotate clockwise to increase time before gate closes.
Rotate counter clockwise to decrease time before gate closes.
If program switch #3 is on, the gate must activate the open limit
switch in order for the timer to close to operate.

CURRENT SENSITIVITY


Rotate clockwise to decrease sensitivity (more force).
Rotate counter clockwise to increase sensitivity (less force).
WARNING: The CURRENT SENSITIVITY should be adjusted to
prevent injury in the event of someone being entrapped in the gate.
This feature should be periodically tested to assure proper operation.
Refer to SAFETY PRECAUTIONS.

TIMER

TO

CLOSE

CURRENT

SENSITIVITY

Fuses

There are 4 standard automotive type fuses on the 635/636 circuit
board. The EMERGENCY BY-PASS plug is protected by a 15 Amp
fuse. The remaining three fuses (one for each of the 12 Volt outputs)
are 3 amp.

LED ENABLE

LED ENABLE

Enables LEDs for installation and troubleshooting (must be de-
pressed to observe LEDs).

OFF

ON