 DO NOT operate Wobblelight

®

units with the protective dome and cap missing or broken. DO NOT use Wobblelight

®

units with a broken housing or

damaged electrical receptacles. Take any damaged units out of service immediately. Replacement parts and/or repair services are available from
ProBuilt Professional Lighting or a local authorized service center.

 DO NOT exceed the labeled amperage for the Wobblelight

®

accessory outlet (see Accessory Receptacle Instructions).

 DO NOT attempt to remove, alter or disable the Wobblelight

®

circuit breaker.

 Use only designated replacement bulbs of the appropriate type and wattage.

 DO NOT expose Wobblelight

®

to intense heat or sparks from welding slag, cutting torches, metal saws, etc.

 DO NOT expose Wobblelight

®

to corrosive chemicals, excessive paint spray or abrasive blasting materials.

 Disassembly of Wobblelight

®

will void the warranty. Contact ProBuilt Professional Lighting or a local authorized service center for repairs and replacement

parts.


WARNING: Deviation from these instructions may result in the increased risk of fire, electric shock, injury to persons or property damage.

SAVE THESE INSTRUCTIONS

Specific Precautions for Metal Halide Units

400-watt Super Duty Metal Halide Wobblelight

®

WARNING!


The following instructions must be followed in order to avoid the risk of personal injury, property damage and poor lamp performance.

I.

RUPTURE RISKS: Metal halide lamps are constructed of an outer glass bulb with an internal arc-tube. Metal halide arc-tubes operate at high
pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as ballast failure or
misapplication. An arc-tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot
particles. In the event of such a rupture, THERE IS A RISK OFPERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.

TO REDUCE THESE RISKS:

1. Only operate lamp in the enclosed Wobblelight

®

fixture with dome and cap installed and free of damage.

2. Only operate lamp with compatible ballast (see bulb manufacturer catalog or contact ProBuilt Professional Lighting for specific information).
3. Only operate lamp in the upright operating position.
4. Lamp must be turned off for a minimum of 15 minutes at least once per week.
5. Never expose an operating lamp to moisture such as rain, sleet or snow.
6. Replace lamp if outer glass is scratched, cracked or damaged in any way.
7. Replace lamp at or before the end of rated life (see bulb manufacturer catalog for rated life).
8. To avoid risk of serious eye injury from the intense light, do not stare at the operating lamp.

II.

ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass is broken, shut off power immediately
and remove lamp after it has completely cooled.