Instructions for Super Duty Wobblelight

®

assembly:

1. Remove and verify the contents of your Wobblelight

®

carton.

2. Install the bulb (metal halide, halogen or fluorescent) into the socket by screwing the lamp firmly but not forcibly into socket in order to avoid breakage
3. Tighten bulb until it is secure in the socket – do not over tighten.
4. Reinstall the Wobblelight

®

dome / cap assembly by aligning the five mounting holes with the five mounting nuts (note that the dome handle should be aligned with the

power switch).

5. Secure dome with the five mounting screws – do not over tighten.
6. Your assembled Wobblelight

®

is now ready for use.


USE OF

Wobblelight

®


By following the safety and operating instructions in this manual, your Wobblelight

®

should endure normal abuse and last trouble-free for years.

Step 1: Connect Wobblelight

®

to proper electrical power source.


Step 2: Press the “Reset” button on the GFCI (if equipped with GFCI)

Step 2: Turn switch to “on” position.

Step 3: Place Wobblelight

®

in desired location.



ELECTRICAL OPERATION


Your Super Duty Wobblelight

®

is equipped with a 120-volt electrical accessory receptacle pigtail cord.

To avoid possible electrical overload, Wobblelight

®

should only be plugged into 120-volt, 60-Hz electrical service which is protected by a circuit breaker of 20 amps or less.

USE CAUTION to not overload the Super Duty Wobblelight

®

accessory outlet when using power tools and other high-amp devices.

Safe electrical operation depends on many factors including the use of extensions cords of the appropriate gauge, type and length.

ProBuilt Professional Lighting recommends using only 3-wire, 10-gauge extension cords that do not exceed 25 feet in length.

Always follow all applicable safety regulations, company policies and electrical codes.


CIRCUIT PROTECTION

All

Wobblelight

®

Super Duty

models are equipped with an externally re-settable circuit breaker located beneath the power switch. The breaker will trip when the total amperage

load on Wobblelight

®

exceeds 20 amps. If the breaker trips, the lamp circuit and the accessory outlet will be immediately de-energized. The following steps should be taken in the

event of a circuit breaker trip:

1. Disconnect

the

Wobblelight

®

with the tripped circuit breaker from the power source and turn the power switch to the “off” position.

2.

Insure that the power source is 120-volt, 60-Hz, 20-amp (or less) service.

3.

Determine if the Wobblelight

®

accessory plug was electrically overloaded by checking the number and type of all downstream electrical devices that are plugged into the

accessory outlet.

4.

If it is possible that the labeled amperage rating on the accessory outlet was exceeded, disconnect all electrical devices from the accessory outlet and reset the circuit
breaker by pushing the tab back into the breaker until it clicks into position.