background image

Installing IP SDU8 with a ROENDC End Cap

5-4

Installation Guide

Check the level of the pipe assembly. If re-leveling is necessary, loosen the two set screws and
repeat steps a-c above.

Figure 5-8 Checking the pipe assembly’s levels

6 Remove the housing from the packaging.

7 Cut a 30cm (12in) length of Teflon tape.

8 Apply Teflon tape to the threads at the top of the housing.

9 Route the cable from the housing through the bottom opening of the end cap and out its front

as shown in Figure 5-9.

Figure 5-9 Example of the cable routing through the End Cap assembly

Caution

Take care while you are threading the dome onto the End Cap to avoid any damage to the cables.

10 Twisting the cables to avoid tension, screw the housing onto the adapter pipe.

11 Keep turning the housing until tight.

12 Re-check the level of the dome in the two directions shown in Figure 5-8. Re-level if necessary.

13 Route the pigtail cables from the dome through the End Cap.

14 Place any excess cable into the end cap, and ensure the O-ring is in place.

15 Using a wrench for tamperproof screws, attach the cover to the End Cap

Figure 5-10 Attaching the End Cap cover