Control Panel

Mounting Screws (4)

Fig. #RP 8267

CONTROLS/ADJUSTMENTS/REPLACEMENTS

Temperature
Adjust Buttons

Mode Button

LCD Display

Fig. #2000

MILLIVOLT CONTROLS

The pool or spa water temperature is controlled by

the pool heater thermostat on the upper front panel of
the heater. The control center contains an On/Off
switch and one or two thermostats.

Thermostats are fitted with a means of limiting the

upper temperature limit below the maximum level. The
knob stop adjustment ring illustrated below is adjustable
by loosening the set screw, rotating the knobstop ring to
the desired location and retightening the set screw.

SPA TEMPERATURE RANGE POOL TEMPERATURE RANGE

STAND-BY
TEMPRATURE

SET SCREW

KNOB STOP RING

Fig. #8103.2

KNOB STOP SHOWN ABOVE IS

IN THE SPA TEMPERATURE RANGE

24

Bypass

Hi Limit
(Located
in Return
Header)

AGS Hi-
Limit
(Located
in Inlet/
Oulet
Header)

Unitherm
Governor

Drain Plug

Fig #2005

SECTION 4 / SERVICING INSTRUCTIONS

GENERAL LOCATION OF CONTROLS

Drain Plug
(Located in
Return
Header)

Ignition
Control (IID)

Digital

Thermostat
Module

Roll-Out
Switch

Gas Valve

Pilot

CONTROL PANEL REMOVAL

1. Remove (4) screws from sides of control panel.
2. Rotate control panel down until panel stops. Do

not force.

NOTE: Caution must be taken not to damage controls

or wiring.

On-Off Switch
Transformer

Advertising