RP2100 REMOTE CONTROL INSTALLATION

CAUTION: Before installing remote controls to the
RP2100 Digital Heater, read the following:
The Raypak RP 2100 Digital Heater is remote ready in
most cases. The digital liquid crystal (LCD) display
shows the actual pool temperature, operating status,
and service codes (See examples below). The touch
pad on the control panel allows you to select the desired
pool or spa temperature. It also indicates when a remote
system is controlling the heater by displaying REM in
the display. When connecting the RP2100 Digital to a
remote system, identify whether it is a two or three wire
remote system. Select the appropriate instruction listed
below to properly install the remote to the heater.

Important Installation Notes for
Remote or external wiring configuration
• Remote wiring must be run in separate conduit.
• Remote wiring must not be run parallel to High Voltage

lines.

• For runs of under 30 feet, remote wiring should have

stranded conductors with a minimum of 22 AWG,
600V, cable twisting 1.5 to 2.5 and jacketed.

• For runs over 30 feet, the conductors should be a

minimum of 20 AWG, 600V, cable twisting 1.5 to 2.5
inch lay that is shielded and jacketed.

• Maximum cable length of 200 feet.
• For both Two and Three wire remote systems, the

provided P-7 wiring connector must be utilized. Please
refer to the wiring instructions.

Two-Wire Remote Systems:
To remotely select either pool or spa operation (3-wire/2-
function) requires 3 wires to be connected to the heater.
A switch mechanism that will provide contact closure
between HIGH/SPA or LOW/POOL and common, needs
to be supplied. This mechanism can be a 3-way switch
or any other remote control system that provides dry
contact closure for either setting. See remote wiring
instructions on this page.

Two or Three-Wire Remote Operation:
To remotely select a single operating ON/OFF mode (2
wire/single function) requires two wires to be connected
to the heater. This requires a switching mechanism that
can be a 2-way switch or a remote control system with a
single dry contact closure. See remote wiring instruc-
tions on this page.
NOTE: Do Not connect wiring to fireman switch

location.

OFF Mode

Heating in the

POOL Mode

Heating in the

SPA Mode

Remote Mode

26

Remote Wiring Instructions
1.Turn off power to the heater.
2.Turn off gas to the heater.
3.Remove the four screws on the side of the heater

holding the control panel (see figure # 9375)

4.Lay control panel forward towards you. This will provide

access to the back of the temperature control board.

5.Install the remote wire harness on the P7 terminal (see

figure # 9373).

6.For a 3-wire/2 function configuration, connect the

HIGH/SPA wire to the orange wire with the black stripe;
the LOW/POOL wire to the black wire with the orange
stripe; and the common wire to the yellow wire with the
black stripe (see figure # 9373).

7.For the 2-wire/1 function configuration, connect the

orange/black and black/orange wires to one contact
and the yellow/black wire to the other contact (see
figure # 9374).

8.Verify the mode button is in the "OFF" position.

Fig # 9375

Fig # 9373

Fig # 9374

THREE WIRE TWO FUNCTION

TWO WIRE ONE FUNCTION ON/OFF ONLY