Accessories, Multiple lock-out device muffl-air, Silencers – Ross Controls RIGHT ANGLE User Manual

Page 18: Pneumatic energy release verification options

Advertising
background image

18

© 2012, ROSS CONTROLS.

All Rights Reserved.

Accessories

Multiple Lock-out Device

Muffl-Air

®

Silencers

ROSS MUFFL-AIR

®

silencers substantially reduce

exhaust noise levels yet produce little back pressure.
Typical impact noise reduction is in the 20–25 dB range.
Pressure Range: 150 psig (10 bar) maximum.


Model

Dimensions inches (mm)

Weight

Numbers Width

Length Thickness lb (kg)

356A30

3.0 (1.4)

3.0 (1.4)

0.4 (.18)

0.3 (0.1)

For use with any ROSS model with L-O-X

®

capability.

Pop-Up Indicator

Pressure Switch

Pneumatic Energy Release Verification Options

Port NPT

Model

Avg. Dimensions inches (mm) Weight

Size Threads Numbers

C

V

A

B lb (kg)

1/8

Male

5500A1003 2.0

0.8 (21)

2.2 (56)

0.3 (0.1)

1/4

Male

5500A2003 2.0

0.8 (21)

2.2 (56)

0.3 (0.1)

3/8

Male

5500A3013 2.0

0.8 (21)

2.2 (56)

0.3 (0.1)

3/8

Male

5500A3003 5.7

1.3 (32)

3.8 (96)

0.5 (0.2)

1/2

Male

5500A4003 7.0

1.3 (32)

3.8 (96)

0.5 (0.2)

3/4

Male

5500A5013 7.0

1.3 (32)

3.8 (96)

0.5 (0.2)

3/4

Male

5500A5003

15

2.0 (51)

5.6 (142)

1.5 (0.7)

1

Male

5500A6003

18

2.0 (51)

5.6 (142)

1.5 (0.7)

11/4

Male

5500A7013

18

2.0 (51)

5.6 (142)

1.5 (0.7)

11/4 Female 5500A7001

37

2.5 (64)

5.9 (149)

2.3 (1.0)

11/2 Female 5500A8001

38

2.5 (64)

5.9 (149)

2.3 (1.0)

2

Female 5500B9001

50

3.0 (77)

7.3 (185)

3.5 (1.6)

21/2 Female 5500A9002

65

4.0 (102) 6.9 (173)

3.5 (1.6)

* NPT port threads. For BSPP threads, add a “D” prefix to the model number.

Pressure Range: 150 psig (10 bar) maximum.

MUFFL-AIR

®

Silencer

male threads illustrated

Female Pipe Threads
For ports 11/4 through 21/2

Male Pipe Threads
For ports 1/8 through 11/4

• May be installed on all L-O-X

®

and manual L-O-X

®

with EEZ-ON

®

operation valves

with pressure sensing port

• Provides a means to verify the release of downstream pressure to next obstruction

Visual Pop-Up Indicator or Pressure Switch (electrical)

CLAMP for MODULE CONNECTIONS

Specially designed clamps provide a quick and easy assembly or disassembly of

MD3 modules. Two allen-head bolts quickly tighten or loosen the clamp using a

5/32 or 4mm hex key. The clamp contains a plate carrying two O-rings to provide

positive sealing between modules. Order clamp by part number

R-A118-105.

Combined clamp and bracket (below) can be ordered by part number

R-A118-105M.

MOUNTING BRACKET

Two brackets are normally used to mount an FRL to a vertical surface. The mounting

bracket attaches to the module-connecting clamp (see above) with a single screw.

Each bracket then employs two bolts (1/4” or 6mm) to connect the assembly to the

mounting surface. Order bracket and screw by part number

R-A118-103. Combined

bracket and clamp (above) can be ordered by part number

R-A118-105M.

Mounting Bracket

Part No. R-A118-103

Module

Connecting Clamp

Part No. R-A118-105

Combined

Clamp & Bracket

Part No. R-A118-105M

A

B

A

B

Model Inlet Port Verification

Dimensions inches (mm)

Weight

Number Size*

Option

Length

Width

Depth

lb (kg)

988A30

1/8

Pop-Up Indicator 0.98 (25)

0.55 (14) 0.55 (14)

0.03 (0.01)

586A86

1/8

Pressure Switch 4.3 (110)

2.01 (51) 1.22 (31)

0.28 (.12)

* NPT port threads.

Advertising