Series 27 piloted valves with l-o-x control, Series 27 piloted valves with l-o-x, Control – Ross Controls RIGHT ANGLE User Manual

Page 8: L-o-x, Sensing port, Reliable, low-cost control • 3 inch port

Advertising
background image

8

© 2012, ROSS CONTROLS.

All Rights Reserved.

3 Inch L-O-X

®

Valve for Lockout

Five good reasons to equip your pneumatic systems with

our energy isolating L-O-X

®

valve:

Effectiveness: A L-O-X

®

valve not only isolates the equipment

by shutting off air supply, it exhausts stored or residual air

immediately from downstream.
Ease of Use: Air shutoff is simple; just push in the bright red

handle. There’s no turning or twisting and guessing whether

the valve is completely open.

Locking protection: L-O-X

®

valves are designed to allow

secure lock-out upon shutdown, using standard padlocks.
Reliability: Special Teflon seals help ensure “shift-ability”

even after long periods of non-use.
Efficiency: Large exhaust ports provide rapid exhaust of

downstream air and are threaded for silencers or remote

exhaust lines.

3" NPT

OUTLET

3" NPT

INLET

Series 27 Piloted Valves with L-O-X

®

Control

VALVE MODEL NUMBERS & OVERALL DIMENSIONS

Port Size

Valve Model

Function

Average Cv

Dimensions inches (mm) Weight

In-Out Exhaust

Number*

1 to 2 2 to 3

A

B

C

lb (kg)

3

21/2

Y3900A0829

Manual

140

140

19.6 (496)

25.3 (643) 11.5 (292) 110 (49.9)

3 21/2

Y3900A0896

Solenoid

140

140

19.6 (496)

25.3 (643) 14.9 (379) 115 (53.0)

*NPT threads, standard.

STANDARD SPECIFICATIONS:
For model 3900A0829 (Manual)
Ambient/Media Temperature:
40 to 175

o

F (4 to 80

o

C).

Flow Media: Filtered air; 5 micron filter recommended.
Inlet Pressure: 30 to 150 psig (2.1 to 10.3 bar).
Pilot Pressure: Must be equal to or greater than inlet pressure.
Port Threads: NPT.
For model 3900A0896 (Solenoid)
Solenoids:
AC or DC power.
Power Consumption: 87 VA inrush, 30 VA holding on 50 or 60
Hz; 14 watts on DC.
Ambient Temperature: 40 to 120

o

F (4 to 50

o

C).

Media Temperature: 40 to 175

o

F (4 to 80

o

C).

Flow Media: Filtered air; 5 micron filter recommended.
Inlet Pressure: 30 to 150 psig (2.1 to 10.3 bar).
Pilot Pressure: Must be equal to or greater than inlet pressure.
Port Threads: NPT.
NOTE: Per specifications and regulations, these products are
defined as energy isolation devices, NOT AS EMERGENCY
STOP DEVICES.

• Reliable, Low-Cost Control

• 3 Inch Port

A

B

C

14.6

(371)

10.0

(254)

3.9

(99)

10.0

(254)

14.6
(371)

3.9

(99)

Solenoid Pilot - Model 3900A0896

Manual Pilot - Model 3900A0829

L-O-X

®

Sensing Port

L-O-X

®

Sensing Port - Series 15 manual L-O-X

®

valves and manual L-O-X

®

valves with EEZ-ON

®

operation are now provided with 1/8

NPT sensing ports, enabling installation of a pressure sensing device such as the Pop-Up Indicator or Pressure Switch shown below.
Standards suggest that machine design should include a method for verifying the release of energy after lockout.

The ROSS 988A30 Pop-Up Indicator is constructed for the industrial environment with a brass body and 1/8” NPT connection. It offers
360° visibility and a redundant verification feature. By pushing on the red plunger, the operator can “feel” the presence of pressure
and verify that the indicator is performing its sensing function.

The ROSS 586A86 Pressure Switch offers an electronic pressure sensing option that can be integrated into a safety monitoring system,
which confirms energy isolation throughout the circuit.

Advertising
This manual is related to the following products: