RLM Systems Installation Guide

Version 3.0 © November 2008

29

RLM II for ELECTRONIC DISPENSERS

Diagnostics

Dispenser-Specific Troubleshooting

GILBARCO

PROBLEM

ANALYSIS/RECOMMENDATION

LED (D5) is off and never flashes.

Console/POS not communicating with dispensers.

LED (D5) is on solid.

! Adapter cable connected incorrectly.
! Wrong type adapter communications input used — RS422 or current loop. Refer to

Diagram: RLM II Adapter Board Switch Selections.

! Defective cable.

All communications down on console/POS
to dispensers.

! Adapter cable not connected.
! Adapter cable connected incorrectly.
! Wrong type adapter communications input used — RS422/current loop.

Refer to Dispenser Specific Installation, RLM II for Gilbarco Electronic Dispenser
section.

! Defective cable.

GILBARCO MOC G-SITE

PROBLEM

ANALYSIS/RECOMMENDATION

No data capture.

! Is EMC port on G-SITE enabled?
! Is correct software version being used on G-SITE?
! Is adapter cable plugged into correct port on G-SITE?
! Is correct type of adapter being used?

Refer to Diagram: RLM II Adapter Board Switch Selections.

RLM II-GS not answering G-SITE.

Are setting correct on the adapter board? Refer to Diagram: RLM II Adapter Board Switch
Selections for proper jumper selections.