2. OIT Installation

It is necessary to follow all installation procedures described in this chapter for

electrical noise immunity and CE compliance.

2.1. Set Jumper for Specific Protocol

This step is required for a few protocols only. Consult the Protocol Guides in your

documentaion. If the protocol requires RS-485 half-duplex 3-wire

communication, proceed as follows.

STEPS

1. Remove the protective cover from the rear of the unit.
CAUTION: When the rear cover is removed, the circuitry inside is exposed to

possible damage by electrostatic discharge. Refer to Static Awareness on page 4.
2. Locate jumper “JP4” using Figure 3 as a guide. The jumper is installed on

the upper two pins of a 3-pin header. This is called Position “A”.

3. Move the jumper to the lower two pins of the 3-pin header (Position “B”).

Ensure that the jumper is pressed fully into place.

4. Replace the rear cover and the four retaining screws.

8

MAP460D

1010-0093, REV 03

JP4

B

A

Normal

A

Position "A",

Half-Duplex 3-Wire

Position "B",

JP4

RS485

B

(Display)

(CPU Board)

B

JP4

A

Figure 3 MAP460D Jumper Installation