10. System Design

*1 For supported models, refer to Pro-face’s support site “Otasuke Pro!”

(http://www.pro-face.com/otasuke/).
You can connect to this site by clicking the GP-Pro EX’s [Help(H)] menu-[Connect to
Support Site “Otasuke Pro!” (C)] command.

*2 Up to 63 CANopen slaves can be connected to the CANopen Master Unit’s CANopen

I/F (master) with CANopen recommended transfer cables and connectors.
See ‘13.4 CANopen Communication Cable and Connectors” on page 11.

*3 When the CANopen Master Unit is used, the EX modules cannot be attached to the LT’s

back together.

CANopen
Master Unit

*3

LT Interface

(1) AUX Unit Interface/Expansion Unit (EXT2)

CANopen Master Unit Interface

(2) Extension Connector

(3) CANopen Interface

LT

IO Cable (Prepared by user)

Various types of I/O
equipment
Indicators, LEDs,
sensors, switches,
and so on

CANopen Slaves
(Commercial type)

*1, *2

IO Cable (Prepared by user)

Various types of I/O
equipment
Indicators, LEDs,
sensors, switches,
and so on

CANopen Slaves
(Commercial type)

*1, *2

(1)

(2)

(3)

Advertising