Internal switches of the control box – Proface APL3000B - Node Box PC User Manual

Page 6

Advertising
background image

6

1.

Internal switches of the control box

System Set Switch

Switch

Location

Switch Name

Compati-

ble I/F

Factory

Settings

Description

SW1

System Set Switch

See

System

Set Switch

10-point DIP switch. For System Set
Switch and the factory settings
details, see

System Set Switch.

SW2

Serial Mode Select
Switch

COM1

All OFF
(RS-232C)

10-point DIP switch. Designates
COM1 communication settings. For
Serial Mode Select Switch details,
see

Serial Mode Select Switch.

SW3

CI(RI)/+5V
Changeover Switch

COM2

CI(RI)

Changes # 9 pin (CI(RI) / +5V).

SW4

CI(RI)/+5V
Changeover Switch

COM1

CI(RI)

Changes # 9 pin (CI(RI) / +5V).

Switch

No.

Description

ON

OFF

Factory

Settings

Notes

1

Internal setting

Reserved Reserved OFF

Do not change.
(Factory setting)

2

Implements the
logical inversion
operation for
RAS output

Normal
Close

Normal
Open

OFF

RAS output is a CLOSE state when the
switch and the system is ON. When the
Switch is OFF, it is the opposite. The
RAS Output keeps Normal OPEN
when the Soft OFF state occurs or the
power turns OFF.

3

Sets up an
enabled/disabled
state for the front
USB port execution
control function

*1

*1

The Setting up an enabled/Disabled state for USB port execution control function is available for
only Windows

®

2000 and Windows

®

XP. Make sure to disable the function of the setting when

other OS is used.

Enabled Disabled ON

The front USB port is available when
the switch is ON. It is unavailable when
the switch is OFF.

4

Internal setting

Reserved Reserved

OFF

Do not change.
(Factory setting)

5 to 8

ON

9 to 10

OFF

1 10

1 10

SW4

SW1

SW2

SW3

OFF

ON

ON

OFF

Bottom face of the control box

(CI)RI

5V