Internal switches of the front module – Proface APL3000B - Node Box PC User Manual

Page 8

Advertising
background image

8

Serial Mode Select Switches (SW4 to SW10) operate as shown in the circuit diagram below.

*1

Refer to *2 on the previous page.

2.

Internal switches of the front module

Touch Panel Set Switch

Switch

Location

Switch Name

Factory

Settings

Description

SW1

Touch Panel
Set Switch

1:ON, 2:ON,
3:OFF, 4:OFF

4-point DIP switch. For Touch Panel Set Switch
details, see “ Touch Panel Set Switch”.

SW2

1:OFF, 2:OFF,
3:ON, 4:OFF

Internal setting.
Do not change. (Factory setting)

Switch

No.

Description

ON

OFF

Factory

Settings

Notes

1 to 2

Internal setting

Reserved Reserved

ON

Do not change.
(Factory setting)

3

OFF

4

Cancellation function
of two point touch on
the touch panel

*1

*1

When two points are pushed, it is considered that middle point between the two points is touched
according to the nature of the analog resistive touch panel. When the switch, etc. is set on the middle
point, it will be enabled and may operate. To prevent such a switch from malfunction in case of pushing
two points, turn ON the Switch No.4 in advance, then the middle point will be disabled for two point
touch.

Enabled

Disabled OFF

The middle point is not considered
to be touched when the switch is
ON. It is considered to be touched
when the switch is OFF.

*1

RT(RTS) Automatic
control

SW1

SW2

ON

ON

Rear face of the front module

Advertising