Yokogawa AXFA14G/C User Manual

Page 49

Advertising
background image

IM 01E20F02-01E

8-5

8. PARAMETER LISTS

T0802-2.EPS

Write

Mode

Explanation

Factory

Default

Relative

Index

Parameter Name

Index

The linearization type of sensor output. AXF is "linear with input"

N/A. For the future use.

N/A. For the future use.

This parameter is used to select the language for use on the
display. Now only 1: English is available.

This parameter is used in order to set the LCD display mode.
1: Flow Rate (%) 2: Flow Rate 3: Integrator1 Out
4: Integrator2 Out 5: Arithmetic Out can be selected.

This parameter is used in order to set the LCD display mode.
1: Off 2: Flow Rate (%) 3: Flow Rate 4: Flow Rate (Bar)
5: Integrator1 Out 6: Integrator2 Out 7: Arithmetic Out 8: PD Tag
9: Adhesion Check 10: Communication can be selected.

This parameter is used in order to set the LCD display mode.
1: Off 2: Flow Rate (%) 3: Flow Rate 4: Flow Rate (Bar)
5: Integrator1 Out 6: Integrator2 Out 7: Arithmetic Out 8: PD Tag
9: Adhesion Check 10: Communication can be selected.

This parameter is used in order to select the unit of size
(diameter) of the sensor (flowtube).

This parameter is used in order to set the size (diameter) of the
sensor (flowtube). If the set value exceeds the valid range, the
warning "72:Size Set Err" will be displayed.

Sets the time constant of damping for the flow rate calculation.

This parameter execute the automatic zero adjustment function:
If "2:Execute" is selected, this function will be started. "Now Auto
Zero Executing..." is indicated whle the Auto Zero function being
carried out and after finishing the adjustment, this parameter is
set to "1:Cancel". The result of the automatic zero adjustment is
confirmed using MAGFLO_ZERO, and if the result exceeds the
rated value, the warning"82:Auto Zero Wng" will be displayed.

This parameter shows the current zero point compensation value
for the sensor. This parameter is used to display the results
obtained from AUTO_ZERO_EXE. Specifically, the correction
values displayed, and it is also possible to directly enter correction
values. This parameter must not be downloaded by the operator

This parameter is used in order to set the low-frequency meter
factor.

This parameter is used in order to set the high-frequency meter
factor.

This parameter is used in order to set the low-frequency meter
factor as required when Enhanced DF (i.e., enhanced dual
frequency excitation) is selected. If "Standard DF" has been
selected for MEASURE_MODE, neither LOW_MF (EDF) nor
HIGH_MF (EDF) is displayed.

This parameter is used in order to set the high-frequency meter
factor as required when Enhanced DF (i.e., enhanced dual
frequency excitation) is selected.

Always 1:ADMAG AXF

Selects measurement mode for dual frequency.
Selectable 1: Standard DF 2: Enhanced DF.

Set the low cut range corresponding 0 to 10% of the range.

Set the mode of the flow measurement, either unidirectional or
bidirectional.

28 2028

30 2030

LANGUAGE

1:

English

Auto

31

2031 DISPLAY_SELECT1

2: Flow Rate

Auto

32 2032

DISPLAY_SELECT2

1:

Off

Auto

33 2033

DISPLAY_SELECT3

1:

Off

Auto

34 2034

1013:

mm

O/S

35 2035

NOMINAL_SIZE

100

O/S

36 2036

3.0

O/S

37 2037

AUTO_ZERO_EXE

1:

Cancel

Auto

40 2040

HIGH_MF

1.0000

O/S

41 2041

LOW_MF(EDF)

1.0000

O/S

42 2042

HIGH_MF(EDF)

1.0000

O/S

43

2043

1: ADMAG AXF

O/S

44

2044 MEASURE_MODE

1: Standard DF

O/S

45 2045

0

O/S

46 2046

BI_DIRECTION

1:

Unidirectional O/S

Assign an arbitrary positive or negative sign to the measured
PV value.

1. Positive
2: Negative

47 2047

FLOW_DIRECTION 1:

Positive

O/S

38 2038

MAGFLOW_ZERO

0.00

O/S

39 2039

LOW_MF

1.0000

O/S

29 2029

1061:

m/s

O/S

27

2027 LIN_TYPE

1: linear with input

O/S

PRIMARY_VALUE_
FTIME

NOMINAL_SIZE_
UNIT

SECONDARY_
VALUE_UNIT

SECONDARY_
VALUE

SELECT_FLOW_
TUBE

PRIMARY_VALUE_
LOWCUT