IM 01E20F02-01E

8-10

8. PARAMETER LISTS

T0803-2.EPS

Write

Mode

Explanation

Factory

Default

Relative

Index

Parameter Name

Index

Raw value of the field device in percent of the PV range, with a
status reflecting the Transducer condition, before signal
characterization (L_TYPE), filtering (PV_FTIME),
or low cut (LOW_CUT).

This alert is generated by any change to the static data.

The block alarm is used for all configuration, hardware,
connection failure or system problems in the block. The cause of
the alert is entered in the subcode field. The first alert to become
active will set the Active status in the Status attribute. As soon as
the Unreported status is cleared by the alert reporting task,
another block alert may be reported without clearing the Active
status, if the subcode has changed.

The current alert status, unacknowledged status, unreported
states, and disabled states of the alarms associated with the
function block.

Selection of whether alarms associated with the block will be
automatically acknowledged.

Amount the PV must return within the alarm limits before the
alarm condition clears. Alarm Hysteresis is expressed as a
percent of the PV span. 0 to 50.

Priority of the high high alarm.
0, 1, 3 to 15.

The setting for high high alarm in engineering units. (Note 1)

Priority of the high alarm.
0, 1, 3 to 15.

The setting for high alarm in engineering units. (Note 1)

Priority of the low alarm.
0, 1, 3 to 15.

The setting for low alarm in engineering units. (Note 2)

Priority of the low low alarm.
0, 1, 3 to 15.

The setting for low low alarm in engineering units. (Note 2)

The status of high high alarm and its associated time stamp.

The status of high alarm and its associated time stamp.

The status of low alarm and its associated time stamp.

The status of low low alarm and its associated time stamp.

20 4020

UPDATE_EVT

1

(Acknowledged) -

22 4022

ALARM_SUM

0

-

23 4023

ACK_OPTION

0xffff

Auto

24 4024

ALARM_HYS

0.50%

Auto

25 4025

HI_HI_PRI

0

Auto

26 4026

HI_HI_LIM

1:

INF

Auto

27 4027

HI_PRI

0

Auto

28 4028

HI_LIM

1:

INF

Auto

29 4029

LO_PRI

0

Auto

32 4032

LO_LO_LIM

-1:

INF

Auto

33 4033

HI_HI_ALM

1

(Acknowledged) Auto

34 4034

HI_ALM

1

(Acknowledged) Auto

35 4035

LO_ALM

1

(Acknowledged) Auto

36 4036

LO_LO_ALM

1

(Acknowledged) Auto

30 4030

LO_LIM

-1:

INF

Auto

31 4031

LO_LO_PRI

0

Auto

21 4021

BLOCK_ALM

1

(Acknowledged) -

19

4019 FIELD_VAL

Bad - O/S

-

Note 1: An intended set value can be written only if Min (XD_SCALE.EU100, XD_SCALE.EU_0)

≤ the intended value ≤ + INF

Note 2: An intended set value cannot be written if -INF

Ϲ the intended value Ϲ Min (OUT_SCALE.EU0, OUT_SCALE.EU100).