App index, Contact, Thermocouple – Yokogawa Standalone MW100 User Manual

Page 14

Advertising
background image

1-7

IM MW100-17E

Commands

1

2

3

App

App

Index

• Contact

Input Type

Contact

String

DI

Measuring Range

Level

Contact

String

LEVEL

CONTACT

Setting Range for Lower/Upper

Limit of Span

0 or 1 (0 for less than 24 V,

1 for 24 V or more)

0 or 1 (0 for contact OFF, 1

for contact ON)

Difference Computation

–1, 0, 1

–1, 0, 1

• Thermocouple

Input Type

Thermo-

couple

String

TC

Measuring Range

Type R

Type S

Type B

Type K

Type E

Type J

Type T

Type N

Type W

Type L

Type U

KPvsAu7Fe

PLATINEL

PR40-20

NiNiMo

WRe3-25

W/WRe26

Type N (AWG14)

Type XK GOST

String

R

S

B

K

E

J

T

N

W

L

U

KPvsAu7Fe

PLATINEL

PR40-20

NiNiMo

WRe3-25

WWRe26

N14

XK

Setting Range for Lower/Upper

Limit of Span

0.0 to 1760.0 °C

0.0 to 1760.0 °C

0.0 to 1820.0 °C

–200.0 to 1370.0 °C

–200.0 to 800.0 °C

–200.0 to 1100.0 °C

–200.0 to 400.0 °C

0.0 to 1300.0 °C

0.0 to 2315.0 °C

–200.0 to 900.0 °C

–200.0 to 400.0 °C

0.0 to 300.0 K

0.0 to 1400.0 °C

0.0 to 1900.0 °C

0.0 to 1310.0 °C

0.0 to 2400.0 °C

0.0 to 2400.0 °C

0.0 to 1300.0 °C

–200.0 to 600.0 °C

Differential Computation

±1760.0 °C

±1760.0 °C

±1820.0 °C

±1570.0 °C

±1100.0 °C

±1300.0 °C

±600.0 °C

±1300.0 °C

±2315.0 °C

±1100.0 °C

±600.0 °C

±300.0 K

±1400.0 °C

±1900.0 °C

±1310.0 °C

±2400.0 °C

±2400.0 °C

±1300.0 °C

±800.0 °C

• RTD

Input Type

RTD

String

RTD

Measuring Range

Pt100

[1]

[2]

JPt100

[1]

[2]

Pt100

[1]

(high

[2]

resolution)

JPt100

[1]

(high

[2]

resolution)

Ni100 SAMA

Ni100 DIN

Ni120

Pt50

Cu10 GE

Cu10 L&N

Cu10 WEED

Cu10 BAILEY

J263B

Cu10 at 20°C

a=0.00392

Cu10 at 20°C

a=0.00393

Cu25 at 0°C

a=0.00425

String

Pt100-1

Pt100-2

JPt100-1

JPt100-2

Pt100-1H

Pt100-2H

JPt100-1H

JPt100-2H

Ni100SAMA

Ni100DIN

Ni120

Pt50

Cu10GE

Cu10LN

Cu10WEED

Cu10BAILEY

J263B

Cu10a392

Cu10a393

Cu25

Setting Range for Lower/Upper Limit

of Span

–200.0 to 600.0 °C

–200.0 to 250.0 °C

–200.0 to 550.0 °C

–200.0 to 250.0 °C

–140.00 to 150.00 °C

–140.00 to 150.00 °C

–200.0 to 250.0 °C

–60.0 to 180.0 °C

–70.0 to 200.0 °C

–200.0 to 550.0 °C

–200.0 to 300.0 °C

–200.0 to 300.0 °C

–200.0 to 300.0 °C

–200.0 to 300.0 °C

0.0 to 300.0 K

–200.0 to 300.0 °C

–200.0 to 300.0 °C

–200.0 to 300.0 °C

Differential Computation

±800.0 °C

±450.0 °C

±750.0 °C

±450.0 °C

±290.00 °C

±290.00 °C

±450.0 °C

±240.0 °C

±270.0 °C

±750.0 °C

±500.0 °C

±500.0 °C

±500.0 °C

±500.0 °C

±300.0 K

±500.0 °C

±500.0 °C

±500.0 °C

The number in brackets for the setting range is the RTD measurement current (mA). If no number is

given, 1 mA, 2 mA, or both are supported.

1.3 Parameters