p2 Data type
MODBUS_MC Modbus master command

status

MODBUS_MC Modbus master connection

status

MODBUS_CC Modbus client command

status

MODBUS_CS Modbus client connection

status

BALANCE

Strain input initial
balance

p3 First data number
MODBUS_MC 1 to 100
MODBUS_MS 1 to 247
MODBUS_CC 1 to 100
MODBUS_CS 1 to 10
BALANCE

1 to 60

p4 Last data number
MODBUS_MC 1 to 100
MODBUS_MS 1 to 247
MODBUS_CC 1 to 100
MODBUS_CS 1 to 10
BALANCE

1 to 60

Example

Output the Modbus master connection status of data
number 1 to 10.
FL1,MODBUS_MS,1,10

IS

Output of Status Information

Setting

ISp1<terminator>
p1 Outputs status information (0)

Example

Output status information.
IS0

VF

Output of Relay Status

Setting

VFp1<terminator>
p1 Outputs relay status (0)

Example

Output relay status.
VF0

CF

Output of System Recognition

Status

Setting

CFp1<terminator>
p1 Outputs system recognition status (0)

Example

Output the system recognition status
CF0

ME

Output of Media Information

Setting

MEp1,p2<terminator>
p1 Output type
0

Outputs media free space

1

Outputs file information

p2 User name (up to 63 characters)
Enter using the full path.

Example

• Output file information.
ME0
• Output the information of MW100.txt in the DATA0

directory.

ME1,/DATA0/MW100.txt
• Output root directory information.
ME1,/

1.8 Output Commands