Index – Yokogawa DAQWORX User Manual

Page 38

Advertising
background image

3-7

IM WX1-07E

Funct

ons

1

2

3

Index

Alarm Type on Devce Sde

Alarm Type after Change
PV

SP

OUT, HOUT, COUT

De-energized on deviation high limit
alarm for target setpoint

Other [ETC]

Deviation high limit [DH]

De-energized on deviation low limit
alarm for target setpoint

Other [ETC]

Deviation low limit [DL]

De-energized on deviation high and low
limits for target setpoint

Other [ETC]

Other [ETC]

Deviation within high and low limits for
target setpoint

Other [ETC]

Other [ETC]

Deviation high limit with stand-by
actions for setpoint

Other [ETC]

Deviation high limit [DH]

Deviation low limit with stand-by actions
for setpoint

Other [ETC]

Deviation low limit [DL]

De-energized on deviation high limit
alarm with stand-by actions for target
setpoint

Other [ETC]

Deviation high limit [DH]

De-energized on deviation low limit
alarm with stand-by actions for target
setpoint

Other [ETC]

Deviation low limit [DL]

Deviation high or low limit with stand-by
actions for setpoint

Other [ETC]

Other [ETC]

Deviation within high and low limits with
stand-by actions for target setpoint

Other [ETC]

Other [ETC]

Target SP high limit

Other [ETC]

SP high limit [H]

Target SP low limit

Other [ETC]

SP low limit [L]

Cooling-side control output high limit

Other [ETC]

Output high limit [H]

Cooling-side control output low limit

Other [ETC]

Output low limit [L]

Analog input PV high limit

Other [ETC]

Analog input PV low limit

Other [ETC]

Analog input RSP high limit

Other [ETC]

Analog input RSP low limit

Other [ETC]

Analog input AIN2 high limit

Other [ETC]

Analog input AIN2 low limit

Other [ETC]

Analog input AIN4 high limit

Other [ETC]

Analog input AIN4 low limit

Other [ETC]

Feedback input high limit

Other [ETC]

Feedback input low limit

Other [ETC]

Displayed in brackets ([ ]) on DAQLOGGER and Remote Monitor.

Furthermore, for the VJ series, all alarm types are Other [ETC].

Alarm types are loaded from each connected device upon start of acquisition by

GateCONTROL. Even if alarm types are changed on the connected device after

acquisition starts, the alarm types valid upon start of acquisition are used.

The number of UT551 and UT520 alarms is four (fixed). To ensure compatibility, also set

the number of UT55A and UT52A alarms to four.

The number of UT351 and UT321 alarms is three (fixed). To ensure compatibility, also

set the number of UT35A and UT32A alarms to three.

The number of UP550 and UM331 alarms is four (fixed). To ensure compatibility, also set

the number of UP55A and UM33A alarms to four.

The number of UP35A alarms is two (fixed).

3.3 Detals on Functons