XIII. UNIT NUMBER DESCRIPTION

Digit

E X X — 1 2 3 4 5 6 7 8 9 10

11

12

13

14

15

16

17 +

Item

Prefi

x

UT

CA

FT FM RA CO GT GC SV MT MS AI AC

AS

(Internal use Only)

1, 2 - Unit Type [UT]

RT - Natural Vent Rooftop
PV - Power Vented Rooftop
AH - Air Handler
EV - Evaporative Cooler Only

3, 4 - Capacity [CA]

Single Furnace

Double Furnace

10 - 100,000 BTU/HR

50 - 500,000 BTU/HR

15 - 150,000 BTU/HR

60 - 600,000 BTU/HR

20 - 200,000 BTU/HR

70 - 700,000 BTU/HR

25 - 250,000 BTU/HR

80 - 800,000 BTU/HR

30 - 300,000 BTU/HR
35 - 350,000 BTU/HR

Triple Furnace

40 - 400,000 BTU/HR

12 - 1,200,000 BTU/HR

5 - Furnace / Access Type [FT]

A - Standard Temperature Rise (20-60 Deg. F), Right Side Access
B - Standard Temperature Rise (20-60 Deg. F), Left Side Access
*C - High Temperature Rise (60-90 Deg. F), Right Side Access
*D - High Temperature Rise (60-90 Deg. F), Left Side Access
0 - None
Z - Other
*Note: Unit Type [PV] not available in Capacity [30].

6 - Furnace Construction Material [FM]

1 - Aluminized Steel
2 - 409 Stainless Steel (First Furnace Only)
3 - 409 Stainless Steel (All Furnace Sections)
4 - 321 Stainless Steel (First Furnace Only)
5 - 321 Stainless Steel (All Furnace Sections)
6 - 409 Stainless Steel Package (First Furnace Only)
7 - 409 Stainless Steel Package (All Furnace Sections)
8 - 321 Stainless Steel Package (First Furnace Only)
9 - 321 Stainless Steel Package (All Furnace Sections)
0 - None
Z - Other

7 - Rooftop Arrangement

(B - L assumes furnace sections)

[RA]

A - Duct Furnace

M - Air Handler (Standard)

B - Blower (Standard)

N - Air Handler (Standard) / Plenum

C - Blower (Standard) / Plenum

P - Air Handler (Standard) / Evap.

D - Blower (Standard) / Evap.

R - Air Handler (Standard) / Evap. / Plenum

E - Blower (Standard) / Evap. / Plenum

S - Air Handler (High CFM)

G - Blower (High CFM)

T - Air Handler (High CFM) / Plenum

J - Blower (High CFM) / Plenum

U - Air Handler (High CFM) / Cooling

K - Blower (High CFM) / Cooling

W - Air Handler (High CFM) / Cooling /Plenum

L - Blower (High CFM) / Cooling / Plenum

0 - None

Z - Other

8 - Coil Options [CO]

A - DX Coil, 4 Row, Single Circuit

E - Chilled Water Coil, 4 Row

B - DX Coil, 4 Row, Dual Circuit

G - Chilled Water Coil, 6 Row

C - DX Coil, 6 Row, Single Circuit

0 - None

D - DX Coil, 6 Row, Dual Circuit

Z - Other (Special)

9 - Gas Type [GT]

1 - Natural Gas
2 - LP Gas (Propane)
3 - Natural Gas w/100% Shutoff
0 - None

10 - Gas Control [GC]

A - Single Stage Gas (Standard)
B - Two Stage Gas
H - Electronic Modulation w/Room Sensing
J - Electronic Modulation w/Duct Sensing
K - Electronic Modulation w/Duct Sensing & Ovrd. Stat
L - Electronic Modulation w/External 4-20 mA Input (Furnace One)
M - Electronic Modulation w/External 4-20 mA Input (All Furnaces)
N - Electronic Modulation w/External 0-10 VDC Input (Furnace One)
P - Electronic Modulation w/External 0-10 VDC Input (All Furnaces)
R - Two Stage Remote Temperature Control w/Duct Sensor
S - Three Stage Remote Temperature Control w/Duct Sensor
T - Four Stage Remote Temperature Control w/Duct Sensor
U - S-350 2 Stage Modular Electronic Control System
W - S-350 3 Stage Modular Electronic Control System
X - S-350 4 Stage Modular Electronic Control System
Y - S-350 6 Stage Modular Electronic Control System
0 - None
Z - Other

11 - Supply Voltage [SV]

1 - 115/1/60

5 - 230/3/60

2 - 208/1/60

6 - 460/3/60

3 - 230/1/60

7 - 575/3/60

4 - 208/3/60

0 - None

Z - Other

12 - Motor Type [MT]

1 - Open Drip Proof (Standard)

4 - Premium Effi ciency, Totally Enclosed

2 - Totally Enclosed

0 - None

3 - Premium Effi ciency, Open Drip Proof

Z - Other

13 - Motor Sizes [MS]

A - 1/2 HP. w/Contactor

M - 1-1/2 HP. w/Mag. Starter

1 - 1 HP. VFD

B - 3/4 HP. w/Contactor

N - 2 HP. w/Mag. Starter

2 - 1-1/2 HP. VFD

C - 1 HP. w/Contactor

P - 3 HP. w/Mag. Starter

3 - 2 HP. VFD

D - 1-1/2 HP. w/Contactor

R - 5 HP. w/Mag. Starter

4 - 3 HP. VFD

E - 2 HP. w/Contactor

S - 7-1/2 HP. w/Mag. Starter

5 - 5 HP. VFD

G - 3 HP. w/Contactor

T - 10 HP. w/Mag. Starter

6 - 7-1/2 HP. VFD

H - 5 HP. w/Contactor

U - 15 HP. w/Mag. Starter

7 - 10 HP. VFD

J - 1/2 HP. w/Mag. Starter

0 - None

8 - 15 HP. VFD

K - 3/4 HP. w/Mag. Starter

Z - Other

L - 1 HP. w/Mag. Starter

14 - Air Inlet Confi guration [AI]

1 - Outside Air (OA)

4 - Outside Air and Return Air (OA/RA)

2 - Outside Air w/Air Hood

5 - Outside and Return Air w/Air Hood

3 - Return Air (RA)

0 - None

Z - Other

15 - Air Control & Damper Arrangement [AC]

A - Outside Air 2 Pos. Motor / Spring Return
B - Return Air 2 Pos. Motor / Spring Return
C - OA/RA 2 Pos. / Spring Return
D - OA/RA Mod. Mtr. w/Mixed Air Control / Min. Pot.
E - OA/RA Mod. Mtr. w/Mixed Air Control / Min. Pot. / SR
G - OA/RA Mod. Mtr. w/Mixed Air Control
H - OA/RA Mod. Mtr. w/Mixed Air Control / SR
J - OA/RA Mod. Mtr. w/Min. Pot.
K - OA/RA Mod. Mtr. w/Min. Pot. / SR
L - OA/RA Mod. Mtr. w/Dry Bulb / Mixed Air Control / Min. Pot.
M - OA/RA Mod. Mtr. w/Dry Bulb / Mixed Air Control / Min. Pot. /SR
N - OA/RA Mod. Mtr. w/Enthalpy Controlled Economizer / SR
P - OA/RA Mod. Mtr. w/Pressure Control (Space Pressure)
Q - OA/RA Mod. Mtr. w/Carbon Dioxide (CO

2

) R/A Monitor

R - OA/RA Mod. Mtr. w/S-350-P Proportional Mixed Air Control / SR
S - OA/RA Mod. Mtr. w/0-10 VDC & 4-20 mA Analog Input (External Input)
T - OA/RA Mod. Mtr. w/0-10 VDC & 4-20 mA Analog Input / SR (External Input)
U - ASHRAE Cycle I (OA/RA 2 Pos. Mtr. w/Warm-up Stat / SR)
W - ASHRAE Cycle II (OA/RA Mod. Mtr. w/Warm-up Stat / Mixed Air / Min. Pot. / SR)
X - ASHRAE Cycle III (OA/RA Mod. Mtr. w/Warm-up Stat / Mixed Air / SR)
Y - Manual Dampers
0 - None

MOD = Modulating Damper Motor

Z - Other

OA = Outside Air RA = Return Air SR = Spring Return

16 - Accessories [AS]

A1 - Moisture Eliminators

H1 - Return Firestat

A2 - Horizontal Return

H2 - Supply Firestat

A3 - Low Leak Damper

H3 - Freezestat w/Time Delay

A5 - Furnace Drip Pan, 409 Stainless

H4 - Ambient Lockout - Single Furnace

A6 - High Altitude Unit

H6 - Ambient Lockout - Dual Furnace

A7 - High Pressure Regulator

H7 - Ambient Lockout - Triple Furnace

A8 - Unit De-rate

J1 - Interlock Relay - 24V Coil DPDT 10A, Plug-in

B1 - Filters - 1" WA (Standard)

J2 - Interlock Relay - 24/115V Coil SPDT 10A

B2 - Filters - 2" WA

J3 - Interlock Relay - 24/115/230V Coil DPDT 10A

B3 - Filters - 2" TA

J4 - Interlock Relay - 24V Coil 4PDT 10A

B4 - Filters - 1" 30%
B5 - Filters - 2” 30%

K1 - Manual Reset High Limit Switch

K2

-

High / Low Gas Pressure Limit Switches

C1 - Evap. Cooler - Fill & Drain Kit

K3 - Status Lamp (Elec. Cabinet)

C2 - Evap. Cooler - 12" CELdek

®

Media K4

-

Fan Time Delay (Arrangement “A” Only)

C3 - Evap. Cooler - Freezestat

K5 - Air Flow Prove Switch (Dwyer 1910-0)

w/o Time Delay
C4 - Evap. Cooler - 8" GLASdek

®

Media

L1 - 30 Amp, Fused Disconnect Switch

C5 - Evap. Cooler - 12" GLASdek

®

Media

L2 - 30 Amp, Non Fused Disconnect Switch

L3 - 60 Amp, Fused Disconnect Switch

D1 - Time Clock - 7 Day

L4 - 60 Amp, Non Fused Disconnect Switch

D2 - Time Clock - 24 Hour

N2 - Through the Base Utility Penetration

E1 - Clogged Filter Switch

N3 - Service Convenience Package

E2 - G.F.I. Convenience Outlet 115VAC

N6 - Double Wall Construction

E3 - Remote Control Panel
E4 - Manual Blower Switch

R1 - Field Installed VFD

R2 - Factory Installed VFD

F1 - Ductstat - One Stage

R3 - VFD Remote Keypad for use with w/R1

F2 - Ductstat - Two Stage

R4 - CO

2

Sensor - 100% OA

R5 - CO

2

Sensor - Mixed Air

G1 - Thermostat - T87K w/Subbase

R6 - Pressure Sensor

G2 - Thermostat - T87K w/Subbase & Guard R7

-

2-Speed VFD Relays

G3 - Thermostat - T834N w/Subbase (Sterling Stat) R8

-

3-Speed VFD Relays

G4 - Thermostat - TB8220U - 7 Day Programmable
G5 - Thermostat - TH5220D (Two Stage)

0 - None

G6 - Locking Thermostat Cover

Z - Other (Specify)

Note: All thermostats are mercury free.

† = Field Installed