Installing the Humidifi er

For ease of service, keep a minimum space of 24” in front of the unit.

15.1

Remove the cover by turning the two 1/4 turn screws to the left and pull the cover towards you.

15.2

Remove the white wire connected on the water pan at the bottom of the unit. This is the overfl ow

sensor.

15.3

Remove the water pan by lifting the front off its holding screw and pull towards you. Do not remove

those screws from the humidifi er middle wall.

15.4 The

humidifi er must be installed on a vertical surface. Because of the length of the steam hose

supplied, select the location of the unit as close as possible within a maximum of 4 feet of the diffuser.
Please see Fig. 15.a for necessary clearances around the humidifi er.

15.5

A rigid drain pipe has to be installed under the unit and connected to the main house drain. We

recommend a 1” minimum I.D. tube or standard 1-1/2” I.D. ABS plumbing tube to do the installation. Please

!

12”

6”

3”

12”

Fig. 15a