CONTRACT

OR

Page 29

Number of

fl

ashes

of

the

red light

Error Description

Humidi

fi er

Status

Actions

to

be

T

aken

by the T

echnician

Reset

OFF

No error

The humidi

fi

er is working

fi ne

None

Countinuous

ON

The

fl

ood sensor under the tank

senses water in the pan.

Humidi

fi

er immediately suspends the

ongoing operation. Heating elements

and supply valve are switched of

f.

T

urn the main power OFF

, then

- Check the drain tube

- Check for abnormal leaks

Automatic Reset when

switching main power

ON

1

The two water level sensors are

miswired or do not read the water

level properly

.

Humidi

fi

er attempts to operate, then

stops because of wrong information

from water level sensors.

T

urn the main power OFF

, then

- Check that the water level

sensors are in the right order

-

Clean

the

sensors

Automatic Reset when

switching main power

ON

2

This code is not used on this

model - Reserved for future use

3

Inadequate water supply

.

The

supply valve was open for more

than 4 minutes.

Humidi

fi

er immediately suspends the

ongoing operation. Heating elements

and supply valve are switched of

f.

T

urn the main power OFF

, then

check the water supply circuit

Automatic Reset when

switching main power

ON

4

Inadequate drainage.

The tank

did not drain or the draining cycle

is too long.

Humidi

fi

er immediately suspends the

ongoing operation. Heating elements

and supply valve are switched of

f.

T

urn the main power OFF

, then

check the drain tube

Automatic Reset when

switching main power

ON

5

The fan is not running.

Humidi

fi

er immediately suspends

the ongoing operation.

The unit goes

back to normal operation as soon as

the error condition disappears.

Check the wiring between the fan

module and steam generator

.

Automatic Reset

when error conditions

disappear

6

T

emperature inside the tank

exceeded the high temperature

cut-out setting.

The high temperature cut-out has

tripped. The

humidi

fi er

immediately

suspends the ongoing operation.

Heating elements and supply valve

are switched of

f.

T

urn the main power OFF

, then

- Check the steam hose for kinks

or blockage

-

This is a very serious condition

After pushing on the

thermal cut-out button,

automatic reset when

switching main power

ON

22.