KEYPAD FUNCTIONS

Transmission fluid is emptied completely from the used fluid tank inside the ATX-2 into
a bulk used tank for proper disposal. This procedure is performed when the used fluid
tank is full or the used fluid tank capacity is not sufficient to perform selected
exchange. The ATX-2 buzzer will sound continuously until the stop button is pushed
when procedure is complete. Refer to page 11 for complete instructions.

Used after the exchange process if fluid level is too high on the transmission dip stick.
Removes ½ quart of fluid from the transmission. Fluid is moved by the vehicle
transmission pump into the used fluid tank of the ATX-2. The ATX-2 buzzer will sound
continuously until the stop button is pushed when procedure is complete. Refer to
page 9 for complete instructions.

Used after the exchange process if fluid level is too low on the transmission dip stick.
Adds ½ quart of transmission fluid to the transmission from the ATX-2 new fluid tank.
Fluid is moved by the pump inside the ATX-2. The ATX-2 buzzer will sound
continuously until the stop button is pushed when procedure is complete. Refer to
page 9 for complete instructions.

Stops any procedure the moment it is pushed, also used at the end of a procedure to
acknowledge completion of process and turn buzzer off.

Illuminates when battery connection is backwards.

Illuminates when the used tank is too full or flashes when the capacity remaining is
less than exchange amount selected. The EMPTY Used procedure must be run to
continue operation of the ATX-2.

Illuminates when the new fluid tank is empty or flashes when the new fluid level is less
than the selected exchange amount. The operator must add fluid to the new fluid tank
of the ATX-2 through the fill port.

Illuminates

when the vehicle engine is running and connected properly to the ATX-2.

Illuminates when the selected process is complete. The buzzer will sound
continuously when this is illuminated.

Caution:

Always use fingers to operate keypad. Use of sharp objects will cause damage
and void the warranty
.