background image

Programming

125

NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel

"^" Button Commands (Cont.)

^BMP

Assign a picture to
those buttons with
a defined address
range.

Syntax:

"'^BMP-<vt addr range>,<button states range>,<name of bitmap/

picture>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).

name of bitmap/picture = 1 - 50 ASCII characters.

Example:

SEND_COMMAND Panel,"'^BMP-500.504&510.515,1,bitmap.png'"

Sets the OFF state picture for the buttons with variable text ranges of 500-504 & 510-515.

^BNC

Clear current
TakeNote
annotations.

Syntax:

"'^BNC-<vt addr range>,<command value>'"

Variable:

variable text address range = 1 - 4000.

command value = (0= clear, 1= clear all).

Example:

SEND_COMMAND Panel,"'^BNC-973,0'"

Clears the annotation of the TakeNote button with variable text 973.

^BNN

Set the TakeNote
network name for
the specified
Addresses.

Syntax:

"'^BNN-<vt addr range>,<network name>'"

Variable:

variable text address range = 1 - 4000.

network name = Use a valid IP Address.

Example:

SEND_COMMAND Panel,"'^BNN-973,192.168.169.99'"

Sets the TakeNote button network name to 192.168.169.99.

^BNT

Set the TakeNote
network port for
the specified
Addresses.

Syntax:

"'^BNT-<vt addr range>,<network port>'"

Variable:

variable text address range = 1 - 4000.

network port = 1 - 65535.

Example:

SEND_COMMAND Panel,"'^BNT-973,5000'"

Sets the TakeNote button network port to 5000.

^BOP

Set the button
opacity.

The button opacity can be specified as a decimal between 0 - 255, where zero (0) is
invisible and 255 is opaque, or as a HEX code, as used in the color commands by
preceding the HEX code with the # sign. In this case, #00 becomes invisible and #FF
becomes opaque. If the opacity is set to zero (0), this does not make the button inactive,
only invisible.

Syntax:

"'^BOP-<vt addr range>,<button states range>,<button opacity>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).

button opacity = 0 (invisible) - 255 (opaque).

Example:

SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,200'"

Example 2:

SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,#C8'"

Both examples set the opacity of the buttons with the variable text range of 500-504 and
510-515 to 200.