AMX Modero NXT-1200V User Manual

Page 48

Advertising
background image

Installation Procedures: NXD-1200V Panels

36

NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel

9.

Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective
locations (outside the conduit box) on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or
NetLinx Master.

10.

Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

Installing the NXD into drywall using Expansion Clips

Expansion clips are mounted through the four oval holes located at the top and bottom of the panel. As the
screw is tightened, the clip bends toward the insertion hole and into the wall. This bending creates a "grip" on
the wall by either pressing onto the wall or by securing the drywall between the housing and the drywall clip.

The most important thing to remember when mounting the NXD is that the outer frame (Mounting Tabs) must
be installed flush against the mounting surface.

1.

Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.

2.

Cut out the surface for the 12-inch Wall Mount using the dimensions shown in FIG. 39. Be sure to cut out
the four notches along the top and bottom areas to accommodate the four drywall expansion clips
(provided).

3.

Remove the magnetic faceplate/bezel (A in FIG. 40) from the main NXD unit (B in FIG. 40) by gripping
the faceplate and pulling with gentle outward force.

FIG. 39

NXD-1200V 12-inch Wall Mount panel dimensions using expansion clips

FRONT BEZEL

CUTOUT

Advertising