Bvn ^bvp ^bvt ^bww ^cpf – AMX Modero NXT-1200V User Manual

Page 140

Advertising
background image

Programming

128

NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel

"^" Button Commands (Cont.)

^BVN

Set the computer
control remote
host for the
specified address.

Syntax:

SEND_COMMAND <DEV>,"'^BVN-<vt addr range>,<remote host>'"

Variables:

variable text address range = 1 - 4000.

remote host = 1 - 50 ASCII characters.

Example:

SEND_COMMAND Panel,"'^BVN-500,191.191.191.191'"

Sets the remote host to '191.191.191.191' for the specific computer control button.

^BVP

Set the network
password for the
specified address.

Syntax:

"'^BVP-<vt addr range>,<network password>'"

Variable:

variable text address range = 1 - 4000.

network password = 1 - 50 ASCII characters.

Example:

SEND_COMMAND Panel,"'^BVP-500,PCLOCK'"

Sets the password to PCLOCK for the specific PC control button.

^BVT

Set the computer
control network
port for the speci-
fied address.

Syntax:

"'^BVT-<vt addr range>,<network port>'"

Variable:

variable text address range = 1 - 4000.

network port = 1 - 65535.

Example:

SEND_COMMAND Panel,"'^BVT-500,5000'"

Sets the network port to 5000.

^BWW

Set the button
word wrap
feature to those
buttons with a
defined address
range.

By default, word-wrap is Off.

Syntax:

"'^BWW-<vt addr range>,<button states range>,<word wrap>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).

word wrap = (0=Off and 1=On). Default is Off.

Example:

SEND_COMMAND Panel,"'^BWW-500,1,1'"

Sets the word wrap on for the button’s Off state.

^CPF

Clear all page flips
from a button.

Syntax:

"'^CPF-<vt addr range>'"

Variable:

variable text address range = 1 - 4000.

Example:

SEND_COMMAND Panel,"'^CPF-500'"

Clears all page flips from the button.