5.5 Roland XV-5080

Note: The XV-5080 only supports audio outputs via R-Bus, not inputs.

Digital Clock (Slave)
Press SYSTEM.
Press F2 (Outp&EQ)
Change Master Clock to “R-Bus”
Change Master Freq to match the Sampling Rate you will use.
[External Clock will change to “In Lock” in the screen indicating that the Roland device is
locked to the V-Fire digital clock.]
Change the Output Mode to Parallel.

Output from XV-5080
Press PERFORM.
Press F5(Effects).
For each part, select the output you wish to use.
The numbers 1-8 correspond to individual R-Bus channels 1-8.
Letters A – D are pairs of R-Bus Channels. (i.e. A is R-Bus 1/2, B is R-Bus 3/4, etc.)


5.6 Roland MV-8000, Using the Onboard LCD Screen

Digital Clock (Slave)
Press SYSTEM and cursor to R-Bus.
Press ENTER.
Cursor to Word Clock, and use the VALUE Wheel to select External.