To display all the scheduler profiles configured in the runtime configuration for the system, use the
show scheduler-profileall command.

FCX and ICX 6450 platforms

The following tables show the default values for the scheduling type for stacking and stand-alone FCX
and ICX 6450 platforms.

Default values for scheduling type for stacking systems (for FCX and ICX 6450 platforms).

TABLE 13

Traffic Class

SP

SP Jumbo

WRR

WRR Jumbo

Mixed

Mixed Jumbo

TC0

SP

SP

3

8

15

15

TC1

SP

SP

3

8

15

15

TC2

SP

SP

3

8

15

15

TC3

SP

SP

3

8

15

15

TC4

SP

SP

3

8

15

15

TC5

SP

SP

10

16

25

25

TC6

SP

SP

75

44

SP

SP

TC7

SP

SP

SP

SP

SP

SP

Default values for scheduling type for stand-alone systems (for FCX and ICX 6450
platforms).

TABLE 14

SP

SP Jumbo

WRR

WRR Jumbo

Mixed

Mixed Jumbo

TC0

SP

SP

3

8

15

15

TC1

SP

SP

3

8

15

15

TC2

SP

SP

3

8

15

15

TC3

SP

SP

3

8

15

15

TC4

SP

SP

3

8

15

15

TC5

SP

SP

3

8

25

25

TC6

SP

SP

7

8

SP

SP

TC7

SP

SP

75

44

SP

SP

Quality of Service

FastIron Ethernet Switch Traffic Management Guide

25

53-1003093-03