Fcx and icx 6450 platforms – Brocade FastIron Ethernet Switch Traffic Management Guide User Manual
Page 27
To display all the scheduler profiles configured in the runtime configuration for the system, use the
show scheduler-profileall command.
FCX and ICX 6450 platforms
The following tables show the default values for the scheduling type for stacking and stand-alone FCX
and ICX 6450 platforms.
Default values for scheduling type for stacking systems (for FCX and ICX 6450 platforms).
TABLE 13
Traffic Class
SP
SP Jumbo
WRR
WRR Jumbo
Mixed
Mixed Jumbo
TC0
SP
SP
3
8
15
15
TC1
SP
SP
3
8
15
15
TC2
SP
SP
3
8
15
15
TC3
SP
SP
3
8
15
15
TC4
SP
SP
3
8
15
15
TC5
SP
SP
10
16
25
25
TC6
SP
SP
75
44
SP
SP
TC7
SP
SP
SP
SP
SP
SP
Default values for scheduling type for stand-alone systems (for FCX and ICX 6450
platforms).
TABLE 14
SP
SP Jumbo
WRR
WRR Jumbo
Mixed
Mixed Jumbo
TC0
SP
SP
3
8
15
15
TC1
SP
SP
3
8
15
15
TC2
SP
SP
3
8
15
15
TC3
SP
SP
3
8
15
15
TC4
SP
SP
3
8
15
15
TC5
SP
SP
3
8
25
25
TC6
SP
SP
7
8
SP
SP
TC7
SP
SP
75
44
SP
SP
Quality of Service
FastIron Ethernet Switch Traffic Management Guide
25
53-1003093-03