On brocade icx 6610 and icx 6450 devices – Brocade FastIron Ethernet Switch Traffic Management Guide User Manual

Page 57

Advertising
background image

device(config-if-e1000-1)# unknown-unicast limit 65536

The combined number of inbound Unknown Unicast packets permitted

for ports 1 to 12 is now set to 65536

device(config-if-e1000-1)#

NOTE
On the SX-FI48GPP module, multicast and unknown-unicast limiting use the value defined in broadcast
limiting. You cannot set a separate limit for unknown-unicast limiting and multicast limiting.

Syntax: [no] broadcast limit num

Syntax: [no] multicast limit

Syntax: [no] unknown-unicast num

The num variable specifies the maximum number of packets per second. It can be any number that is a
multiple of 8192, up to a maximum value of 2147418112. If you enter the multicast limit or unknown-
unicast limit
command, multicast packets or unknown-unicast limit are included in the corresponding
limit. If you specify 0, limiting is disabled. If you specify a number that is not a multiple of 8192, the
software rounds the number to the next multiple of 8192. Limiting is disabled by default.

On Brocade FCX Series, ICX 6430 , and ICX 6650 devices

To enable broadcast limiting on a group of ports by counting the number of packets received, enter
commands such as the following.

device(config)# interface ethernet 1/1/1 to 1/1/8

device(config-mif-e1000-1/1/1-1/1/8)# broadcast limit 65536

To include unknown unicast limiting by counting the number of packets received, enter commands such
as the following.

device(config-mif-e1000-1/1/1-1/1/8)# unknown-unicast limit

To include multicasts limiting, enter the multicast limit command after enabling broadcast limiting.

device(config-mif-e1000-1-8)# multicast limit

Syntax: [no] broadcast limit num

Syntax: [no] multicast limit

Syntax: [no] unknown-unicast limit

The num variable specifies the maximum number of packets per second. It can be any number that is a
multiple of 65536, up to a maximum value of 2147418112. If you enter the multicast limit command,
multicast packets are included in the corresponding limit. If you specify 0, limiting is disabled. If you
specify a number that is not a multiple of 65536, the software rounds the number to the next multiple of
65536. Limiting is disabled by default.

On Brocade ICX 6610 and ICX 6450 devices

To enable broadcast limiting on a group of ports by counting the number of bytes received, enter
commands such as the following.

device(config)# interface ethernet 1/1/1 to 1/1/8

device(config-mif-e1000-1/1/1-1/1/8)# broadcast limit 8192

On Brocade FCX Series, ICX 6430 , and ICX 6650 devices

FastIron Ethernet Switch Traffic Management Guide

55

53-1003093-03