Store-and-forward – Brocade FastIron Ethernet Switch Traffic Management Guide User Manual

Page 96

Advertising
background image

The following example displays information for all the scheduler profiles configured in the system:

Device(config)# show qos scheduler-profile all

User Scheduler Profile: user1 Scheduling Option: Weighted round-robin

Ports attached: 1/1/1

Per Queue details: Bandwidth%

Traffic Class 0 1%

Traffic Class 1 1%

Traffic Class 2 10%

Traffic Class 3 10%

Traffic Class 4 10%

Traffic Class 5 10%

Traffic Class 6 20%

Traffic Class 7 38%

User Scheduler Profile: user2 Scheduling Option: Strict scheduling

Ports attached: --

User Scheduler Profile: user3 Scheduling Option: Mixed-SP-WRR

Ports attached: --

Per Queue details: Bandwidth%

Traffic Class 0 15%

Traffic Class 1 15%

Traffic Class 2 15%

Traffic Class 3 15%

Traffic Class 4 15%

Traffic Class 5 25%

Traffic Class 6 sp

Traffic Class 7 sp

User Scheduler Profile: user4 Scheduling Option: Weighted round-robin

Ports attached: --

Per Queue details: Bandwidth%

Traffic Class 0 3%

Traffic Class 1 3%

Traffic Class 2 3%

Traffic Class 3 3%

Traffic Class 4 3%

Traffic Class 5 3%

Traffic Class 6 7%

Traffic Class 7 75%

History

Release version

Command history

8.0.10

This command was introduced.

store-and-forward

Syntax

store-and-forward

no store-and-forward

Command Default

By default, ICX 7750 runs in cut-through mode

Parameters

None

Modes

Global configuration mode

Usage Guidelines

The no form of this command restores the default packet forwarding settings to cut-through mode.

There are two basic methodologies used for packet forwarding decisions that you can set on your
ethernet switch. These include store-and-forward and cut-through mode. ICX 7750 supports cut-through

store-and-forward