Peri-trunk – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual

Page 151

Advertising
background image

no peri-port stack-unit/slotnum/portnum

Parameters

stack-unit

Specifies the stack unit ID.

slotnum

Specifies the slot number.

portnum

Specifies the port number in the slot.

Modes

Stack unit configuration mode

Usage Guidelines

This command can also be used to convert a port that is already configured as part of a peripheral trunk
on a backbone device to a peripheral port.

Any one backbone device supports a maximum of two single (untrunked) port connections to peripheral
devices. The no form of this command removes the port configuration.

Examples

The following example specifies that ports 1 and 2 on a backbone device connect to a peripheral device
in a substack.

Brocade(config-unit-1)# peri-port 1/3/1

Brocade(config-unit-1)# peri-port 1/3/2

History

Release

Command History

08.0.00a

This command was introduced.

peri-trunk

Specifies a trunk on a backbone device that connects to a peripheral device in a substack

Syntax

peri-trunk stack-unit/slotnum/portnum to stack-unit/slotnum/portnum

no peri-trunk stack-unit/slotnum/portnum to stack-unit/slotnum/portnum

Parameters

stack-unit

Specifies the stack unit ID.

slotnum

Specifies the slot number.

portnum

Specifies the port number in the slot.

Modes

Stack unit configuration mode

Usage Guidelines

This command can also be used to convert a port that is already configured as a peripheral port on a
backbone device to a peripheral trunk.

The first port in a peripheral trunk must be an odd-numbered port, for example, 1/3/1.

peri-trunk

FastIron Ethernet Switch Stacking Configuration Guide

149

53-1003090-02