Syslog messages for phy calibration – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual

Page 44

Advertising
background image

When a stack unit reloads, the stack unit generates a syslog message similar to the following:

SYSLOG: <9>3d21h52m57s : ICX6610-24P Router Stack: unit 3 Reload u3 in 10 sec due

to 3/2/6 port problems. reason: lose one nbr

SYSLOG: <9>0d00h08m59s : ICX6610-48 Router Stack: unit 2 U3 detects stack port

problem. will reload u2: one directional CPU to CPU: u2 --> u3, one directional CPU

to CPU: u2 --> u4,

When the entire stack reloads, the active controller generates a syslog message similar to the
following:

SYSLOG: <9>0d00h12m07s : ICX6610-48 Router Stack: "stack stack-port-resiliency 3"

is configured. Active u3 reloads the stack in 5s. reason: no CPU to CPU: u1 -x- u4,

no CPU to CPU: u2 -x- u4, no CPU to CPU: u3 -x- u4,

SYSLOG: <9>0d00h12m28s : ICX6610-24P Router Stack: "stack stack-port-resiliency 3"

is configured. Active u1 reloads the stack in 5s. reason: 1: 1/2/1 (T0) --->

2/2/6 (T1) *** error: one-way 2: 1/2/2 (T0) ---> 2/2/7 (T1) *** error:

one-way 3: 1/2/3 (T0) ---> 2/2/8 (T1) *** error: one-way 4: 1/2/4 (T0) ---

> 2/2/9 (T1) *** error: one-way 5: 1/2/5 (T0) ---> 2/2/10(T1) ***

error: one-way one directional CPU to CPU: u2 --> u4,

PHY calibration errors in stack ports of the ICX 6610

On every boot initialization, an ICX 6610 device performs PHY calibration on the 40 Gbps and 4 x10
Gbps stack ports. Sometimes, this calibration is incorrect, and results in CRC errors and link drops on
a port. FastIron IronWare detects the calibration errors and, by default, recovers the port by
recalibrating it. You can use the no snmp-server enable traps nlp-phy-40g command to disable this
recovery of incorrectly calibrated stack ports. To re-enable the default behavior of recalibrating the
incorrectly calibrated stack ports for recovery, use the snmp-server enable traps nlp-phy-40g
command.

Syslog messages for PHY calibration

On boot initialization, an ICX 6610 device in a stack performs PHY calibration on its 40 Gbps and 4
x10 Gbps stack ports, and generates a syslog message. The following syslog message example
shows the calibration of all 16 ports (4 PHY with 4 lanes for each) on an ICX 6610 stack unit.

SYSLOG: <14>0d00h02m52s : ICX6610-48 Router System: Port init success Stack unit 3

Port 3/2/1 Lane 0 T 0 R 0 Type 0: 1630x00000x0000 1640x00000x0000 1710x00000x0000

1580x00000x0000 1630x00000x0000 1630x00000x0000 1640x00000x0000 1630x00000x0000

1670x00000x0000 1680x00000x0000 1690x00000x0000 1680x00000x0000 1650x00000x0000

1680x00000x0000 1660x00000x0000 1640x00000x0000

If any stack port in an ICX 6610 device has the PHY Tx or Rx CMU (voltage) reaching a threshold
value of 31 and the port is re-calibrated, the stack unit generates a syslog message similar to the
following:

SYSLOG: <14>0d00h08m49s : ICX6610-48 Router System: Port init success Stack unit 2

Port 2/2/1 Lane 0 T 22 R 23 Type 0: 10xc0f00x0216 10xc2430x87ea 10xcc080x08dc

10xcc090x08a3 10xcc040x004b 10xcc000x00fb 10xcc010x4880 10xcc0d0x002c 10xefed0x0027

10xef020x8000 10xef030xfa66 10xef040x8000 10xef050xfd03 10xeffc0x0001 10xeff90x0000

10xeff90x0000 10xeff60x0000 10xeff60x0000 10xeffd0x0000 10xefd20xc6ec 10xefd30x8121

10xefeb0x08a3 10xd0800x0ab9 10xd08f0x00fe 10xc0f20x0000 10xcc0a0x0668 10xcc0b0x0b6e

10xcc0c0x08e1 10xd0080x0001 10xd0920x0001 10xc20c0x1880 10xefe10x0000 10xefe20x0000

10xefe30x0000 10xefe40x0000 10xef2c0x00a9 10xefcc0x00a9 10xeffe0x0004 10xeffe0x0004

10xeffe0x0004 10xeff70x0000 10xeff80x0000 10xeff60x0000 10xca140x82f8 10xca440x82f8

30x00200x100d 30x00210x80ff 10xd0920x0001 10xca240x0001 10xca250x00e1 10xca260x0001

10xca270x0100 10xca280x0000 10xca290x1010 10xca2a0x1314 10xca2b0x1010 10xca2c0x8000

10xca2d0x0000 10xd0920x0000

PHY calibration errors in stack ports of the ICX 6610

42

FastIron Ethernet Switch Stacking Configuration Guide

53-1003090-02

Advertising