Ag-1012, Ag-1015, Ag-1017 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 96

Advertising
background image

80

Network OS Message Reference

53-1003227-01

AG-1012

8

AG-1012

Message

Sending logout (LOGO) request failed on N_Port <port>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there was a failure sending an N_Port logout request from the Access Gateway to the
fabric switch.

Recommended

Action

Check the configuration of the fabric switch connected to the Access Gateway.

If the message persists, execute the copy support command and contact your switch service provider.

AG-1015

Message

Unable to find online N_Ports to connect to the fabric.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that no other N_Port is configured or all N_Ports are currently offline.

Recommended

Action

Check whether any other N_Port is configured.

If the message persists, execute the copy support command and contact your switch service provider.

AG-1017

Message

No N_Port(s) are currently Online.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that no N_Ports are currently configured in the system or all configured N_Ports have failed to
come online.

Recommended

Action

Run the show fabric islports command to display the status of all ports in the system and run show
running-config interface FibreChannel
to display a list of ports currently configured as N_Ports.

Advertising