Installation location

Devices can be mounted in a standard 19-inch equipment rack, on a flat surface, on a wall, or on a
metal surface.

The site should meet the following requirements:

Maintain the operating environment as specified in the

Environmental considerations

on page

42 section.

Allow a minimum of 7.62 cm (3 in.) of space above the device and between the front and the back
of the device and walls or other obstructions for proper airflow.

Allow at least 7.62 cm (3 in.) of space at the front and back of the device for the twisted-pair, fiber-
optic, and power cabling.

The site should be accessible for installing, cabling and maintaining the devices.

Allow the status LEDs to be clearly visible.

Allow for twisted-pair cables to be routed away from power lines, fluorescent lighting fixtures, and
other sources of electrical interference, such as radios and transmitters.

Allow for the unit to be connected to a separate grounded power outlet that provides 100 to 240
VAC, 50 to 60 Hz, is within 2 m (6.6 ft) of each device, and is powered from an independent circuit
breaker. As with any equipment, a filter or surge suppressor is recommended.

For a 2-post rail mount configuration, order the appropriate mounting kit and refer to the kit
documentation.

When using the magnet mount installation to install the device on a metal surface, the device
cannot be installed above 1.1 meters.

Rack-mount installation considerations

Before mounting the device in a rack, ensure that the following rack-mount installation requirements
are met:

Allow a minimum of 7.62 cm (3 in.) of space above the device and between the front and the back
of the device and walls or other obstructions for proper airflow.

Temperature: Because the temperature within a rack assembly may be higher than the ambient
room temperature, check that the rack-environment temperature is within the specified operating
temperature range. (Refer to

Operating environment

on page 42.)

Mechanical loading: Do not place any equipment on top of a rack-mounted unit.

Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.

Grounding: Rack-mounted equipment should be properly grounded.

Installing the device

You can install the device on a desktop, an equipment rack, a wall, or on a metal surface:

Desktop installation

on page 23

Rack mount installation

on page 23

Wall mount installation

on page 25

Wall mount installation using wall mount brackets

on page 28

Mounting the device with a magnet

on page 30