INSTALLATION GUIDE FOR THE BURCAM’S Fan Air
MODEL F80210

DO NOT INSTALL crawlspace units so that they can extend more than
half way from the ceiling towards the floor of the crawlspace.

For all other units, do not install them so that they extend to a suction
point less than 39'' from the floor of the room.

The ideal location to install your ''FanAir'' is the most humid part of your
dwelling. The unit must be installed at a minimum of 10 feet (3 meters)
from a high heat source like a boiler, a radiator, a baseboard heater or
any other similar heat source. Avoid placing the unit beneath a
bedroom, as the noise of the expelled air may disturb some people.

The unit must be installed inside against an outside wall to allow an
outside exit for the duct. The distance between the unit and the exterior
vent hole should not be more than 24'' (600mm).

Location

Warning

INSTALLATION STEP BY STEP

Select the appropriate location for the ''FanAir'' system. It should be
installed between the 2 X 10 or 2 X 12 (joist) of the basement ceiling.

First, determine the position of the air evacuation
pipe. Make sure the hole location will be above
ground level on the outside. Plan to leave a space
between the pipe and the floor joist to avoid vibra-
tion. After choosing the ideal position, mark the
center opening of the pipe. Then, use a drill and a
drill bit of 1/4'' (6mm) to make a hole representing
the middle of the pipe opening, from inside to the
outside. This hole will be use has a pilot to drill the
final 6 1/4'' (160mm) hole to introduce the evacuation
pipe, to be drilled from the outside to the inside
location.

STEP 1