Options Configuration

33

4.7

Option 7 – Serial I/O

The serial I/O option offers flexibility for an operator to customize the serial output format for individual system
requirements. The selections under option 7 can be divided into three groups.

Customizing of serial output data.

Setup of MACRO files.

Those files that affect serial operation.

These sections are addressed in detail below.

4.7.1

Customizing Files

The serial I/O option offers flexibility for an operator to customize the serial output format for individual system
requirements but must be limited to 30 character codes. The selection of the associated custom print file is
performed automatically by serial port and the data mode (gross, net, total recall, or special) that the UMC600 is
currently in at the time of a print.

The custom print supports:

Specifying starting and terminating characters (STX, CR, LF)

Adding printer control characters

Custom headers and titles

Customizing units to ounce, tons, or pounds

Customized parameters such as gross weight instead of GR

Custom insertion of special parameters such as time/date and identification number

Delays where and when required

Truck mode custom printing

Custom continuous serial protocol

Custom “P” print out in duplex mode

NOTE: Custom print does not support RS485 protocol.

Table 4-10. Customized Serial I/O Forma

Customizing

File

Normal Mode

Truck Mode

Macros (8)

Macro Parameter

Codes

Port 1

7.1

Gross data

Truck mode data is printed only
on Port 2. Port 1 files remain in
normal mode.
Option 7 disabled - unit prints
in default format.
Option 7 enabled - print mode
will print to its default format
unless a designated file is set to
off.

7.9

600

7.2

Net data - must have a tare
weight (press TARE button) for
file 7.2 to be printed.

7.10

601

7.3

Prints total data when totalizer
(option 4) is enabled.

7.11

602

7.4

Special (future use)

7.12

603

Port 2

7.5

Gross data

Truck entry

7.13

604

7.6

Net data - must have a tare
weight (press TARE button) for
file 7.2 to be printed.

Truck out empty

7.14

605

7.7

Prints total data when totalizer
(option 4) is enabled.

Truck out full

7.15

606

7.8

Special (future use)

Truck fixed tare

7.16

607

Advertising