10 hardware configuration, S4 s5, S7 s6 – Rice Lake Condec UMC600 User Manual

Page 11: Jumper pins are provided for, Enable jumper 1-2 disable jumper 2-3, Dual channel (optional), Power on/off relay

Advertising
background image

8

UMC600 Installation Manual

2.10 Hardware Configuration

Jumper pins are provided for:

EPROM chip selection

Front panel switch configuration (DC on/off or batch start)

Power on/off relay configuration

Dual channel (optional)

Time and date option (SRAM selection)

These features are dependent on installed options and software. The location and jumper positions are noted in
Figure 2-10.

Figure 2-10. Jumper Pin Placement

Note:

The lower left corner switch (S21) on the front panel, is used for the Start command in the standard setting of

S4 and S5, however, it becomes a power on/off switch when S4 and S5 are set to DC On/Off and S3 is set to the
Enable position.

RF1

SHIELDED

A/D

U7

U4

J7

K1

J4

R6

J5

J3

F1

S6

TB1

+EXC

SHIELD

–SENSE

+SENSE

–SIG

+SIG

1

6

5

4

3

2

1

7

8

9

10

DIGITAL OUTPUT

6

5

4

3

2

1

LOAD CELL CONNECTOR

U2

Q5

U20

U5

U18

S2

1

3

U11

S7

S4
S5

Enable Jumper 1-2
Disable Jumper 2-3

S7

S6

Dual Channel
(optional)

l 2 3

1 2 3

DC On/Off Jumper 1-2
Batch Start Jumper 2-3

Front Panel On/Off

Switch Function

S3

S3

Power On/Off

Relay

3

2
1

Enable Jumper 1-2

Disable Jumper 2-3

For Toggle Switch Omit Jumper

TB3

Time and Date Option

Enable Jumper 1-2 –

(1243 SRAM U4)

Disable Jumper 2-3 –

(1220 SRAM U4)

EPROM Select

S2

3

2
1

S4
S5

1 2 3

1 2 3

1 2

3

256k Jumper 1-2
512k Jumper 2-3

Advertising