5 vac conversion, 6 board removal, 5 vac conversion 2.6 board removal – Rice Lake Condec UMC600 User Manual

Page 8: Warning

Advertising
background image

Installation and Wiring

5

2.5

VAC Conversion

The UMC600 can be converted from 115VAC to
230VAC. The following steps are necessary to
complete this conversion.

Before beginning, be sure to
disconnect the AC power source.
Failure to do so can result in injury
or death.

1. Disconnect power to the indicator. Loosen cord

grips and remove enclosure as described in
Section 2.2

2. See Section 2.6 for CPU board removal and

replacement instructions.

3. Remove the protective insulator panel from the

solder side of the CPU assembly.

4. Cut circuit traces between E7/E8 and E9/E10 as

indicated with a sharp instrument like a razor
blade or an x-acto knife. Refer to Figure 2-3.

Figure 2-3. Circuit Trace Setup

5. Add jumper, E8 to E9 using a properly insulated

wire with a minimum size of #22 AWG.

6. Replace the protective insulator panel.

7. Change the power cord.

8. Reassemble the unit, test, and label unit for

230VAC.

2.6

Board Removal

If you must remove the UMC600 CPU board, use the
following procedure:

1. Disconnect power to the indicator. Loosen cord

grips and remove enclosure as described in
Section 2.2

2. Unplug all connections to the CPU board noting

where they are connected.

3. Remove the four screws from the corners of the

CPU board.

4. Remove the CPU board from the enclosure.

To replace the CPU board, reverse the above procedure.
Be sure to reinstall tie wraps to secure all cables inside
the indicator enclosure. Replace enclosure and torque
screws to 10 in - lb (1.13 N-m).

Warning

E7

E8 E9

E10

Jumper E8 to E9

Cut between
E7 and E8

Cut between
E9 and E10

Circuit Side of CPU Board

Converting from 115V AC to 230V AC

Advertising